Section 5 – Installation Wiring
This section provides the information necessary to connect the system components.
Power Supply Connections
a) Connect both the console’s IEC mains leads to a suitable mains supply outlet. These leads are supplied
unterminated to simplify connection to the facility’s preferred distribution system.
For live transmissions work it is recommended that one of the power feeds should be from an uninterruptable
source.
THE MAINS SAFETY EARTH MUST BE CONNECTED.
THE TWO POWER SOURCES MUST NOT BE FROM DIFFERENT PHASES OF A 3-PHASE SUPPLY.
The console is fitted with auto-ranging power supplies which will accept mains voltages which range from 100 to
240V without adjustment. The mains rating label is located adjacent to the earth bolt on the power inlet panel.
b) Connect both the Blackrock’s IEC mains leads to appropriate mains supplies. Refer to the notes above for suitable
supply provision.
Console Address
It is only necessary to refer to the console address switch setting if more than one C100HDS console is being connected
to the same Ethernet network.
The address switch is located on the console connector panel – it is a 16-position rotary switch. Its function is to identify
different consoles connected to the same Ethernet network. The default setting for this switch is ‘
1
’.
If a second console is added to a network then the switch should be set to the
‘2’
position – and subsequent positions for
additional consoles. Address
‘0’
is not used.
Installation Wiring
Section 5
Page 25
0
F
E
D
C B
A 9 8 7 6
5
43
2
1
Console Address Switch
Default setting
Содержание C100HDSS
Страница 1: ...Installation Guide ...
Страница 2: ...C100HDS Installation Guide ...
Страница 24: ...C100HDS Installation Guide Page 20 MORSE Router MORSE 3U Stagebox ...
Страница 28: ...Page 24 C100HDS Installation Guide Console Mains Inlet Panel Blackrock Power Supplies ...
Страница 60: ...C100HDS Installation Guide Page 56 This page is intentionally mostly blank ...
Страница 64: ...C100HDS Installation Guide Page 60 ...