Page 48
C100HDS Installation Guide
Blackrock Processor
Parameter
Condition
Value
Unit
Notes
Height
2
U
89
mm
Width
19
in
Case only without rack ears
449
mm
Depth
429
mm
Excludes connectors/cables
Weight (†)
14
kg
Heat Dissipation
200
W
Shared between two PSUs
Voltage
Range
100 – 240
V
±10%, AC only
Current
Maximum over voltage range
2.1 – 0.9
A
Maximum
Power Factor
0.95
Approximately
Fusing
Thermal current trip. No fuses
Noise
Front
50
NR
Two PSUs operating
Rear
55
NR
Two PSUs operating
Connectors
Power in 1 and 2
IEC male
Network/TCP IP
RJ45 100 baseT
Sync in
BNC 75Ω
Madi 1–4 (5–8)
Duplex LC fibre multimode
Video out
HD15 female
† Blackrock processors must be supported on rack shelves. Do not rely on the rack ears alone.