Air Conditioning Requirements
Air conditioning will almost certainly be required for both the Machine and Control rooms in order to maintain the
temperature and humidity to within the required levels.
Power dissipation figures for console control surface and equipment rack are listed in Appendix A.
Appendix E contains the environmental specification for SSL equipment.
Cable Ducting
Cable ducting will be required between the console and the Machine room (as well as to any outboard racks and the
recording areas). The ducting provided should be of sufficient size such that approximately 50mm x 35mm is available for
console surface connection. This should be sufficient for the analogue and digital cabling for metering and the T/B Mic etc.
in addition to the console connections.
The connectors for all control and interface cables are located beneath the console’s Centre Section. The connector
panels are orientated so that cables will exit downwards at the rear of the desk. It is not possible to route cables through
the console legs.
The mains input connectors are located on a separate panel. This panel is normally positioned in the bay to the left of the
Centre Section.
Service Access
Access to all electronic assemblies within the frame is from either the front or above the console. The power supplies are
located in the knee panel area. There are PCB assemblies located behind the channel TFT meter screens. To remove a
TFT screen it will be necessary to remove the top trim. This trim is secured using screws along the rear of the top edge.
If the console is being built into restricted space – as in some mobile installations – then allow sufficient clearance above
the top trim for access to the fixing screws.
Clearance for service access will also be required in front of and behind the rack into which the Blackrock processor is
installed so that cards can easily be removed. See the drawing on page 10 for minimum clearances.
Pre Installation Information
Section 3
Page 9
Содержание C100HDSS
Страница 1: ...Installation Guide ...
Страница 2: ...C100HDS Installation Guide ...
Страница 24: ...C100HDS Installation Guide Page 20 MORSE Router MORSE 3U Stagebox ...
Страница 28: ...Page 24 C100HDS Installation Guide Console Mains Inlet Panel Blackrock Power Supplies ...
Страница 60: ...C100HDS Installation Guide Page 56 This page is intentionally mostly blank ...
Страница 64: ...C100HDS Installation Guide Page 60 ...