Unplugging under load: PV plug connections must not be unplugged while under
load. They can be placed in a no load state by switching off the DC/AC converter or
breaking the DC circuit interrupter. Plugging and unplugging while under voltage is
permitted.
It is unadvisable to use non-tinned cables of type H07RN-F, since with oxidised
copper wires the contact resistances of the crimp connection may exceed the permitted
limits.
Disconnected connectors should be protected from dirt and water with sealing
caps.
Plugged parts are watertight IP67. They can not be used permanently under
water. Do not lay the MC-PV connectors on the roof surface.
See the MC catalogue 2 Solar line for technical data and assembled parts.
PV-Female cable coupler PV-Male cable coupler Optional
PV-KBT4/
… PV-KST4/… PV-SSH4
Touch protection,
mated/unmated
IP67/IP2X
Rated current
17A(1,5mm2/14AWG)
22A(2,5mm2/ 12AWG)
30A(4mm2,6mm2/ 10AWG)
Ambient
temperature
range
-40° ...90°C (IEC/CEI)
-40° ...75°C(UL)
-40° ...70°C(UL/AWG14)
Rated voltage
1000V (IEC/CEI) 600V (UL)
Upper limiting
temperature
105°C (IEC/CEI)
Safety class
II
Tools required
(ill.1) Crimping tool incl. locator and
built-in crimping insert.
Type: PV-ES-CZM-18100
PV-ES-CZM-19100