13
OXYGEN 5000
Type
OXYGEN 5000
Input (DC)
Max. PV-generator power
P
pv
[W]
5000
Max DC voltage
V
max(DC)
[V]
590
MPPT DC voltage range
V
mppt
[V]
120
– 500
Turn off DC Voltage
V
min(DC)
[V]
120
Max. DC current
I
max(DC)
[A]
36
Nominal DC current
I
N(DC)
[A]
33
Number of DC connection
2
DC-connection
MC4
Number of MPP trackers
2
Turn on power
P
min(DC)
[W]
10
Output (AC)
Max. AC Power
P
max(AC)
[V]
4800
Nominal AC power
P
N(AC)
[W]
4600
Max. AC current
I
max(AC)
[A]
21.0
Nominal AC current
I
N(AC)
[A]
20
Power connection
Single phase
Grid voltage range
According to VDE 0126-1-1, RD1663, ENEL2010,C10/11
G83/1 AS4777
Grid frequency range
According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,
G83/1, AS4777
Power factor
0.99 (>30% of Full Load)
Harmonic distortion (THD) at nominal output
<2%
AC Connector
Plug-in connector
Power consumption
Own consumption in operation
P
own(AC)
[W]
50
Power consumption at night
P
nig(AC)
[W]
0
Power consumption at standby
P
std(AC)
[W]
6
Efficiency
Max. Efficiency (at 360VDC)
97.6%
Euro efficiency (at 360VDC)
97.0%
MPPT efficiency
99.9%
Safety and protection
Internal overvoltage protection
Yes
DC Insulation monitoring
Yes
Earth fault protection
Yes
Grid monitoring
According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,
G83/1, AS4777
Earth fault current monitoring
According to VDE 0126-1-1, RD1663, ,ENEL2010,C10/11,
G83/1, AS4777
DC current monitoring
According to VDE 0126-1-1, RD1663, ENEL2010,C10/11,
G83/1, AS4777
Islanding protection
According to VDE 0126-1-1, RD1663, G83/1, AS4777
Normative reference
CE- compliant according to
EN 62109, EN 61000-6-1, EN 61000-6-3, EN 61000-6-2, EN