Figure 6-14: System Network Settings Screen
6.14.3
System Clock / Other Status
This screen allows adjustments to the product’s internal clock. Note that system time is volatile and must
be reset following a power-cycle.
Selecting Clock / Other Status on the System Tab, shown in Figure 6-15, provides display and setting
capability for the IDU’s (battery-powered) real-time clock, as well as system temperatures and IDU host
processor software uptime and load information. The date and time as set here are used in Data and Event
Logging. Changing the time during link operation may result in a discontinuity in logged data and events.
Nominal Mainboard Temperature readings are typically in the range of 20 to 30 degrees above the ambient air
temperature around the IDU. Nominal Power Supply Temperature readings are normally 5 to 10 degrees
below the Mainboard temperature.