26
Figure 5-11: Final position of the waveguide for horizontal polarization.
5.5
Cabling
The IF cable, running between the IDU and ODU, carries the bidirectional IF frequencies (140, 350 MHz)
and the DC power necessary to power the ODU. Solectek recommends the use of either LMR240 or
LMR400 cable. Cable run lengths are limited to the following distances:
Allowable IF Cable Lengths
Cable Type
Max. ft.
Min. ft.
LMR240
250
3
LMR400
500
3
Table 5-1: IF cable length requirements
5.6
Antenna Mounting
The antenna mounting gear and method depends on the antenna manufacturer. Please consult the
mounting instructions that come with your choice of antennas.
Содержание SKYWAY-LM Series
Страница 1: ...1 SKYWAY LM SERIES PTP Microwave Radio System User s Guide APRIL 2010 Rev 1 6 PN 1552601 ...
Страница 21: ...21 Figure 5 2 The backside of the ODU rectangular waveguide version shown ...
Страница 25: ...25 Figure 5 9 Loosened plate Figure 5 10 Rotating the antenna waveguide by 90 degrees ...
Страница 50: ...50 Figure 6 19 System Reboot Screen ...
Страница 57: ...57 Figure 8 3 Serial Interface Menu Structure ...
Страница 66: ...66 Figure 11 2 Frame Structure ...