![Sole Digital Liftlog XL Скачать руководство пользователя страница 39](http://html1.mh-extra.com/html/sole-digital/liftlog-xl/liftlog-xl_installation-and-user-manual_1314522039.webp)
© CASWA Pty Ltd – 2012
39 | Page
Appendix D: DATA FILE FORMAT
Data is recorded each time a motion is detected (a contactor closes). Each datum set contains:
1.
Date/Time (based on the logger’s internal clock – when a user connects to the logger via
Bluetooth using the FSU software, the time is compared to the time on the laptop and can
be reset)
2.
Operator (only used if a logger is bound to an AccessPack)
3.
Hook (1 = main, 2 = Aux, 3 = Both hooks)
4.
Load from load cell/other input in tenths of a tonne
5.
Duration of motion in tenths of a second
6.
Motion code – type of motion as shown in the following table.
Motion
Code
Motion
0
No move
1
Move Up
2
Move Down
4
Move Fast
8
Move East
16
Move West
32
Move North
64
Move South
128
Move Up Fast
256
Move Aux1 / Aux
512
Move Aux2 / Magnet
1024
Move Aux3/Override
2048
Move Aux1 Off
4096
Move Aux2/Magnet Off
8192
Move Aux3/Override Off
Note: If a combined motion is detected, then the sum of the individual motions is recorded