28.
0-10V input for AUX hook from loadcell/pin amplifier or Konecranes Control-
pro
0-10V
AUX
29.
Return connection for AUX hook 4-20mA strain gauge (mA) load cell/pin, or
output from load display
4-20mA
30.
Excitation voltage (3.3V) for AUX hook strain gauge (mv) load cell/pin (red
wire on RC-3 or RC-5 rope clamps)
XCite
31.
+ve sense input for AUX Hook strain gauge (mV) load cell/pin (green wire on
RC-3 or RC-5 rope clamps)
+
32.
-ve sense input for AUX Hook strain gauge (mV) load cell/pin (white wire on
RC-3 or RC-5 rope clamps)
-
33.
GND negative reference for mV, mA, and V sensors (black wire on RC-3 or RC-
5 rope clamps)
GND
34.
Connection for AUX hook to gnd on an ABUS LIS
- Q-Link
35.
Connection for AUX hook to terminal Q, F1, or F2, on an ABUS LIS.
+Q-Link
36.
Drive voltage for 4-20mA sensor
24V
37.
Opto-isolated limit input, can be used for any limit function
AUX2
38.
AUX2
39.
Opto-isolated limit input, can be used for any limit function
AUX1
40.
AUX1
41.
Opto-isolated side pull input for AUX Hook. Connect across up inputs on
SideWise signal processor.
SidePull
AUX
Limits
42.
SidePull
43.
Opto-isolated ultimate limit input for AUX Hook.
Top
44.
Top
45.
Opto-isolated side pull input for MAIN Hook. Connect across up inputs on
SideWise signal processor.
SidePull
MAIN
Limits
46.
SidePull
47.
Opto-isolated ultimate limit input for MAIN Hook.
Top
48.
Top
49.
AUX hook load limit output 48-240VAC 4A NO/NC
Fault2
50.
Fault2
51.
MAIN hook load limit output 48-240VAC 4A NO/NC
Fault1
52.
Fault1