![SolaX Power Triple Power T-BAT PACK-HV Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/solax-power/triple-power-t-bat-pack-hv/triple-power-t-bat-pack-hv_user-manual_1314279004.webp)
2
3
2
Safety
2.1
Safety Instructions
For safety reasons, installers are responsible for familiarizing themselves with the
contents of this manual and all warnings before performing installation.
2.1.1
General Safety Precautions
Observe the following precautions:
Ÿ
Risks of explosion
–
Do not subject the battery pack to strong impacts.
–
Do not crush or puncture the battery pack.
–
Do not dispose of the battery pack in a fire.
Ÿ
Risks of fire
–
Do not expose the battery pack to temperatures in excess of 55°C.
–
Do not place the battery pack near a heat source, such as a fireplace.
–
Do not expose the battery pack to direct sunlight.
–
Do not allow the battery connectors to touch conductive objects such as
wires.
Ÿ
Risks of electric shock
–
Do not disassemble the battery pack.
–
Do not touch the battery pack with wet hands.
–
Do not expose the battery pack to moisture or liquids.
–
Keep the battery pack away from children and animals.
Ÿ
Risks of damage to the battery pack
–
Do not allow the battery pack to get in contact with liquids.
–
Do not subject the battery pack to high pressures.
–
Do not place any objects on top of the battery pack.
T-BAT SYS-HV can be used only in the household energy field. It is not allowed to
be used in other industries, such as the medical equipment and automotive
application.
WARNING!
Please don't crush or impact the battery, and always dispose it
according to the safety regulation.
2.1.2
Explanation of Symbols
This section gives an explanation of all the symbols shown on the T-BAT system
and on the warning label.
CAUTION!
If the battery is not installed within one month after receiving the battery, the
battery must be charged till the SOC is more than 50% for maintenance.
Lithium ion Rechargeable Battery System
Product Name: T-BAT SYS-HV
Max.Charge/Discharge Current: 35A
Ingress Protection: IP 55
Operating Temperature: 0~+55
℃
Storage Temperature: -20~+55
℃
S
ol
aX Power Network Technology (Zhejiang) Co., Ltd
ADD: No.288 Shizhu Road, Tonglu Economic Development Zone,
Dongxing District, Tonglu City, Zhejiang Province, China.
TEL: +86 571 5626 0011 E-mail:
www.solaxpower.com
Made in China
612.01579.00
Rated Capacity: 50Ah
Model No./Nominal Voltage/Rated Capacity
T-BAT H 5.8/115.2Vdc/5.8kWh
IFpP/39/148/95/M/-20+55/90
T-BAT H 11.5/230.4Vdc/11.5kWh
IFpP/39/148/95/M/-20+55/90
T-BAT H 17.3/345.6Vdc/17.3kWh
IFpP/39/148/95/M/-20+55/90
T-BAT H 23.0/460.8Vdc/23.0kWh
IFpP/39/148/95/M/-20+55/90
SN: