![SolaX Power Triple Power T-BAT PACK-HV Скачать руководство пользователя страница 21](http://html1.mh-extra.com/html/solax-power/triple-power-t-bat-pack-hv/triple-power-t-bat-pack-hv_user-manual_1314279021.webp)
36
37
BMS_TemHigh
Battery over
temperature
Wait till the temperature of cells go
back to the normal state.
BMS_TemLow
Battery under
temperature
Wait till the temperature of cells go
back to the normal state.
BMS_CellImblance
The capacities of
cells are different
Please contact SolaX after-sales
service or your distributor directly.
BMS_Hardware_Protect
Battery hardware
under protection
Please contact SolaX after-sales
service or your distributor directly.
BMS_Insulation_Fault
Battery insulation
fault
Please contact SolaX after-sales
service or your distributor directly.
BMS_VoltSensor_Fault
Battery voltage
sensor fault
Please contact SolaX after-sales
service or your distributor directly.
BMS_TempSensor_Fault
Battery
temperature
sensor fault
Please contact SolaX after-sales
service or your distributor directly.
BMS_CurrSensor_Fault
Battery current
sensor fault
Please contact SolaX after-sales
service or your distributor directly.
BMS_Relay_Fault
Battery relay fault
1. Make sure the power cable is
correctly and well connected to
the power connector (XPLUG) of
the BMS;
2. If the rst step still does not
work, please contact SolaX after-
sales service or your distributor
directly.
BMS_SelfChk_Fault
BMS selfcheck
fault
Please contact SolaX after-sales
service or your distributor directly.
Warning Messages
Description
Troubleshooting
6. Troubleshooting
6. Troubleshooting
BMS_CellTempDiff_Fault
The temperature
between cells are
different
Stop charging or discharging for a
while.
BMS_CapMismatch_Fau
lt
The capacity of
battery packs are
different
Please contact SolaX after-sales
service or your distributor directly.
BMS_SlaveSwVer_Mism
atch_Fault
The software
betwen slavers are
different
Please contact SolaX after-sales
service or your distributor directly.
BMS_SlaveSw&HwMism
atch_Fault
The hardware is
different
Please contact SolaX after-sales
service or your distributor directly.
BMS_Manu_Mismatch_F
ault
The cell
manufacture is
different
Please contact SolaX after-sales
service or your distributor directly.
BMS_MasterSw&SlaveS
wMismatch_Fault
The software
between Master
and Slaver are
different
Please contact SolaX after-sales
service or your distributor directly.
BMS_ChgReqNoAck_Fa
ult
No action for
charging request
Check the information from
Inverter.
Warning Messages
Description
Troubleshooting