2. Keep the Inverter off. Connect the other end of power lines (+,-) to the correct
port on the Inverter.
+
-
WiFi
RF
4
8
5
B
M
S
Upgrade
A
C
BAT
DRM
Meter
NOTE!
1. When connecting the cable to Inverter, fit the two connectors together until
the connection audibly locks into place.
2. Check to make sure the connection is securely locked.
3. Don't shake both ends of the cable at the joint once the connection is locked.
4.5.2
Connecting Power Lines
1. Connect the the positive cable (+) (A) and negative cable (-) (B) to the
corresponding port as shown in the following figure.
-
+
BAT-
BAT+
CAN
BAT-
BAT+
CAN
4. Installation
4. Installation
20
21
Connecting Charging Cables between Inverter and T-BAT System:
Ø
This step is going to connect power lines between Inverter and T-BAT system.
The default length of power lines are 2 meters, so customers can appropriately
cut the cable accroding to the actual installation environment. As a result, each
power line has one terminal block when leaving the factory, and customers need
to connect the other end of terminal block by themselves.
Cable Connection Steps:
Ø
Step2
. Insert the stripped cable up to the stop (negative cable for DC plug(-) and
positive cable for DC ) are live). Hold the housing on the screw
connection.
Step3
. Press down spring until it clicks audibly into place (it must be possible to
see the fine wire strands in the chamber)
Step1.
Strip the cable to 15mm.
DC plug housing(-)
DC socket h)
screw connection
screw connection
spring
chamber
wire strands
Step4
. Tighten the screw connection(tighten torque:2.0
±
0.2Nm)
Step2
.
Step3
.
Step 4
.