SolaX Power Triple Power T-BAT PACK-HV Скачать руководство пользователя страница 13

2. Keep the Inverter off. Connect the other end of power lines (+,-) to the correct 
port on the Inverter.

+

-

WiFi

RF

4

8

5

B

M

S

Upgrade

A

C

BAT

DRM

Meter

NOTE!

1. When connecting the cable to Inverter, fit the two connectors together until 
the connection audibly locks into place.
2. Check to make sure the connection is securely locked.
3. Don't shake both ends of the cable at the joint once the connection is locked.

4.5.2 

Connecting Power Lines

1. Connect the the positive cable (+) (A) and negative cable (-) (B) to the 
corresponding port as shown in the following figure.

-

+

BAT-

BAT+

CAN

BAT-

BAT+

CAN

4. Installation

4. Installation

20

21

 Connecting Charging Cables between Inverter and T-BAT System:

Ø

This step is going to connect power lines between Inverter and T-BAT system.

The default length of power lines are 2 meters, so customers can appropriately 
cut the cable accroding to the actual installation environment. As a result, each 
power line has one terminal block when leaving the factory, and customers need 
to connect the other end of terminal block by themselves.

 Cable Connection Steps:

Ø

Step2

. Insert the stripped cable up to the stop (negative cable for DC plug(-) and 

             positive cable for DC ) are live). Hold the housing on the screw 
             connection.

Step3

. Press down spring until it clicks audibly into place (it must be possible to 

             see the fine wire strands in the chamber)

Step1.

 Strip the cable to 15mm.

DC plug housing(-) 

DC socket h)

screw connection

screw connection

spring

chamber

wire strands

Step4

. Tighten the screw connection(tighten torque:2.0

±

0.2Nm)

Step2

.

Step3

.

Step 4

.

Содержание Triple Power T-BAT PACK-HV

Страница 1: ...td SolaX Power Co Ltd Any corporation or individual should not plagiarize partitially or fully copy including software etc and no reproduction or distribution of it in any form or by any means All rig...

Страница 2: ...AGED BATTERIES 5 2 3 QUALIFIED INSTALLER 6 3 PRODUCT INTRODUCTION 7 3 1 PRODUCT OVERVIEW 7 3 1 1 DIMENSION AND WEIGHT 7 3 1 2 APPEARANCE 8 3 2 BASIC FEATURES 10 3 2 1 FEATURES 10 3 2 2 CERTIFICATIONS...

Страница 3: ...indicates a hazardous situation which if not avoided could result in minor or moderate injury NOTE NOTE provides tips that are valuable for the optimal operation of your product 4 5 CABLE CONNECTION...

Страница 4: ...battery pack T BAT SYS HV can be used only in the household energy field It is not allowed to be used in other industries such as the medical equipment and automotive application WARNING Please don t...

Страница 5: ...eyes with flowing water for 15 minutes and seek medical attention immediately Dermal contact Wash the affected area thoroughly with soap and water and seek medical attention immediately Ingestion Indu...

Страница 6: ...ices Knowledge of and adherence to this manual and all safety precautions and best practices 6 7 3 Product Introduction 3 1 Product Overview For safety reasons installers are responsible for familiari...

Страница 7: ...85 Connector to RS485 I of next battery pack Power Connector to XPLUG of next battery pack or to of the same pack Air valve BAT BAT CAN YPLUG RS485 II XPLUG RS485 I YPLUG RS485 II Power Connector to o...

Страница 8: ...3 3 Specifications 3 3 1 T BAT SYS HV Configuration List 3 3 2 Performance Model Battery Pack Energy kWh Voltage V No 1 2 3 4 T BAT H 5 8 T BAT H 11 5 T BAT H 17 3 T BAT H 23 0 T BAT H 5 8 1 T BAT H 5...

Страница 9: ...product installation personnel shall wear safety gears etc in order to avoid short circuit and personal injury Insulated gloves Safety goggles Safety shoes 4 Installation 12 13 4 Installation 4 3 Too...

Страница 10: ...ver plate2 Wall bracket M5 screw Expansion bolt Ring terminal for grounding Power cable disassembling tool Quantity 1 1 1 1 2 8 2 1 1 5 2 1 L HV11550 Quantity Object A1 B1 C1 D1 E1 F1 G1 H1 I1 J1 Desc...

Страница 11: ...are deep enough at least 50mm for installing and tightening the expansion bolts J or I1 Install the expansion bolts in the wall and screw the bracket by using the wrench Step 2 Match the battery with...

Страница 12: ...3 battery packs 1 Connect for T BAT H 5 8 or for HV11550 on the right side to on the left side of the next battery pack 2 Connect YPLUG for T BAT H 5 8 or for HV11550 on the right side to XPLUG on th...

Страница 13: ...p is going to connect power lines between Inverter and T BAT system The default length of power lines are 2 meters so customers can appropriately cut the cable accroding to the actual installation env...

Страница 14: ...system is not turned o otherwise there will be an arc discharge that could cause serious injury CAUTION Disassembling Power Line on BAT BAT XPLUG port 22 23 4 Installation 4 Installation YPLUG RS485...

Страница 15: ...with an orange stripe 2 Orange 3 White with a green stripe 4 Blue 5 White with a blue stripe 6 Green 7 White with a brown stripe 8 Brown Sequence 1 2 3 4 5 6 7 8 CAN GND CAN_H CAN_L A1 B1 4 5 4 Conne...

Страница 16: ...6 Overall Installation It is recommended to protect the cables by using corrugated pipe For T BAT H 5 8 1 Connect all the cables on the left side of T BAT H 5 8 2 Get the cables through the corrugate...

Страница 17: ...ert the series connected plug at and YPLUG on the right side of last battery pack to make a complete circuit CAUTION One T BAT system is allowed to install one T BAT H 5 8 plus at most three battery p...

Страница 18: ...AT H 5 8 5 Matching T BAT H 5 8 1 HV11550 6 Matching T BAT H 5 8 2 HV11550 7 Matching T BAT H 5 8 3 HV11550 Black start configuration 5 Commissioning 5 Commissioning NOTE When powering on the BMS the...

Страница 19: ...her charging nor discharging the indicator lights off When the battery pack is charging part of the Blue LED is flashing with the frequency of light on for 0 5s light off for 0 5s and part of the Blue...

Страница 20: ...tem A warning state is triggered when a condition such as voltage or temperature is beyond the design limitations The T BAT system s BMS periodically reports its operating state to the inverter When t...

Страница 21: ...tor XPLUG of the BMS 2 If the rst step still does not work please contact SolaX after sales service or your distributor directly BMS_SelfChk_Fault BMS selfcheck fault Please contact SolaX after sales...

Страница 22: ...er Disconnect the series wiring terminal on the ended battery Disconnect the other cables 7 2 Packing Please pack the BMS and battery packs with the original packaging If it is no longer available you...

Отзывы: