Electrical Connection
Electrical Connection
57
6.4.4 RSD Transmitter Connection
The APsmart Rapid Shutdown System Transmitter-PLC-1P is part of a rapid
shutdown solution when paired with APsmart RSD-S-PLC (Signal receiver), a
PV module rapid shutdown unit. While powered on, the Transmitter-PLC-1P
sends a signal to the RSD-S-PLC units to keep their PV modules connected
and supplying energy. RSD-S-PLC units automatically enter rapid shutdown
mode when the Transmitter-PLC-1P is switched off and resume energy
production when power is restored to the Transmitter PLC-1P. This solution
complies with NEC 690.12 specifications for 2017&2020 and supports the
SunSpec signaling for rapid shutdown.
Note:
The RSD has been integrated in the inverter before leaving factory.
Note:
If an emergency stop switch is required, the customer needs to
purchase and wire it.
6.4.5 Monitoring Connection
The inverter is equipped with
m
onitoring port which can collect data and transmit it
to monitoring-website via an external monitoring data collector.
6.4.5.1 GATEWAY WIFI &4G Connection (Optional)
1 Take out the x1 gateway and x2 antenna (WiFi antenna and 4G antenna) from the
accessory box.
Gateway Antenna
2 Install the gateway on the communication board and tighten the four plastic studs
on the four corners of gateway (Hand tighten).
NOTE!
WiFi antenna is designed with fool-proof terminal, which differs from
4G antenna.
56
For the RSD connection, the voltage value is 12Vdc, and the current value is
0.7Amax.
The customer just needs to put all the PV+ cables through the CT connected
to the transmitter, the transmitter-PLC-1P has been integrated into the
inverter without wiring.
SolaX may provide several types of monitoring data collector, such as the
2030.5
GATEWAY WiFi (Optional), 2030.5 GATEWAY WIFI&4G (Optional), Pocket
WiFi
(Optional) and MLPE (Optional)..
Users should choose an appropriate product
according to the environment.
Purchase