19
VENTING
This S
Ó
LAS Gas Fireplace has been tested and listed for installation with 4” X 6 5/8” M&G DuraVent
GS/Pro®, Selkirk Direct-Temp®, Security Secure Vent™, AmeriVent Direct™, Metal Fab Direct Vent and ICC
EXCELDirect venting components. Although you may use the pipe components (straight pipe, elbows,
etc.) from any of the listed manufacturers, you may only use the vent terminations (caps) listed in the
chart on the following page. For installations where a snorkel is needed, please note that only three
snorkels are approved for use. Please plan your installation accordingly.
For all specific venting installation requirements, follow the installation instructions included by the
venting manufacturer with the venting system components you have chosen.
PLEASE NOTE:
•
It is assumed that the installation will include at least one 90° elbow. Up to three additional 90°
elbows (or equivalent 45° elbows) may also be used. The total venting may not exceed 30 feet
of vertical rise and/or 12 feet horizontal run. Refer to the venting chart on page
23
for specific
details while you plan your installation. Note: The number of elbows impacts the maximum
allowable horizontal vent run.
•
There should be a 1 1/2” overlap of the vent and combustion air tubes, when telescopic joints
are used.
•
The location of the vent termination must meet the requirements of the current edition of ANSI
Z223.1/NFPA 54, National Fuel Gas Code or CAN B419.1, Natural Gas and Propane Installation
Code and the requirements shown on page
14
of this manual.
APPROVED VENT
TERMINATIONS
M&G DURAVENT
GS/PRO
SELKIRK DIRECT-
TEMP
SECURITY
SECURE VENT
AMP AMERIVENT
DIRECT
METAL FAB
DIRECT VENT
ICC EXCELDIRECT
VERTICAL CAP
46DVAVCH
1604802
SV4CGC
4DVC
4DVT
TM4VT
HORIZONTAL CAP
46DVAHC
46DVAHRCS
46DVAHSC
1604804
SV4GHC
4DVHC
4DHT
TM4HT
TM4DHT
SNORKEL
N/A
1604836
N/A
4D36C
N/A
TMST36
Just as with any other vented device, vertical vent rise creates draft (negative pressure) in the
firebox as the exhaust gases heat up. If this draft becomes excessive, it can affect the performance or
appearance of the fire. The S
Ó
LAS Gas Fireplace includes an integrated air restrictor that can used to
balance the draft in the fireplace to the optimal level for installations where excessive draft might occur.
The S
Ó
LAS Gas Fireplace will ship from the factory with the air restrictor set to the open position. If the
licensed fireplace installer determines that draft reduction is necessary, loosen the fastener on the dial
and make small adjustments from the open position, clockwise to the closed position until a
satisfactory result has been achieved.
Содержание THIRTY8 BI-38N-C
Страница 2: ......
Страница 24: ...23 VENTING...
Страница 28: ...27 CERAMIC BURNER LOGSET INSTALLATION Log 3 Log 4 Log 5 Log 6 Log 7 The Logset is now complete...
Страница 37: ...36 REMOTE HANDSET OPERATION...
Страница 38: ...37 REMOTE HANDSET OPERATION...
Страница 39: ...38 REMOTE HANDSET OPERATION...
Страница 40: ...39 REMOTE HANDSET OPERATION...
Страница 41: ...40 REMOTE HANDSET OPERATION...
Страница 46: ...45 MAINTENANCE LOG CONT...
Страница 51: ...50 V1 7 9 19...