INSTALLATION INFORMATION
State of Massachusetts:
The installation must be completed by a licensed plumber or gas fitter in the Commonwealth of
Massachusetts.
REQUIREMENTS FOR THE COMMONWEALTH OF MASSACHUSETTS
This product must be installed by a licensed plumber or gas fitter when installed within the
Commonwealth of Massachusetts. If this appliance is installed in a dwelling, building or structure
used in whole or in part for residential purposes and the installation includes a horizontal vent
termination that is less than seven (7) feet above the finished grade in the area of the venting,
including but not limited to decks and porches, a hard-wired carbon monoxide detector with an
alarm and battery back-up must be installed on the floor level of the dwelling, building or structure
where the appliance is to be installed.
Additionally, a hard-wired or battery operated carbon monoxide detector with an alarm must be in-
stalled on each additional level of the dwelling, building or structure served by the appliance. It shall
be the responsibility of the property owner to secure the services of qualified licensed professionals
for the installation of hard-wired carbon monoxide detectors.
In the event that the horizontally vented appliance is installed in a crawl space or attic, the hard-
wired carbon monoxide detector with alarm and battery back-up may be installed on the next
adjacent floor level.
In the event that this requirement cannot be met at the time of completion of the installation of the
appliance, the owner shall have a period of thirty (30) days to comply with the requirement. However,
during said thirty (30) day period, a battery operated carbon monoxide detector with alarm must be
installed.
Each carbon monoxide detector as required in accordance with the above provisions must comply
with NFPA 720 and be ANSI/UL 2034 and IAS certified.
In addition, when the vent termination is less than seven (7) feet above finished grade a metal or
plastic identification plate must be permanently mounted to the exterior of the building at a
minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal. The sign
shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP
CLEAR OF ALL OBSTRUCTIONS”.
A COPY OF THESE INSTRUCTIONS PLUS ALL VENTING INSTRUCTIONS WHICH IN-CLUDE PARTS LISTS,
AND/OR ALL VENTING DESIGN INSTRUCTIONS MUST REMAIN WITH THE STOVE AT THE COMPLETION
OF THE INSTALLATION.
ATTENTION INSTALLERS: Mark below which venting system was used in the installation. These
instructions must remain with the S
Ó
LAS Gas Fireplace Installation & Operation Manual.
O
Simpson DuraVent GS/PRO®
O
Selkirk Direct-Temp®
O
Security Secure Vent™
O
AmeriVent Direct™
O
Metal Fab Direct Vent
O
ICC Direct Vent
Содержание THIRTY8 BI-38N-C
Страница 2: ......
Страница 24: ...23 VENTING...
Страница 28: ...27 CERAMIC BURNER LOGSET INSTALLATION Log 3 Log 4 Log 5 Log 6 Log 7 The Logset is now complete...
Страница 37: ...36 REMOTE HANDSET OPERATION...
Страница 38: ...37 REMOTE HANDSET OPERATION...
Страница 39: ...38 REMOTE HANDSET OPERATION...
Страница 40: ...39 REMOTE HANDSET OPERATION...
Страница 41: ...40 REMOTE HANDSET OPERATION...
Страница 46: ...45 MAINTENANCE LOG CONT...
Страница 51: ...50 V1 7 9 19...