The following table describes production percentage of AC information by LED color
and ON/OFF/P switch position.
Indication
ON/ OFF/ P
Switch
Position
LED Color
Comment
Red
Green
Blue
Percentage of AC
Production:
0 %
ON (1)
OFF
OFF
OFF
This indicates power
production as
percentage of rated
peak AC output
power
Percentage of AC
Production:
0 - 33 %
OFF
ON
OFF
Percentage of AC
Production:
33 - 66 %
OFF
OFF
ON
Percentage of AC
Production:
66 - 100 %
OFF
ON
ON
DC Safety Unit Interfaces
The DC Safety Unit, includes:
ON/OFF switch
: For connection/disconnection of the DC power from the PV
strings
AC conduit entries
for connection of AC cable to the grid
DC conduit entries
for connection of the DC wires from the PV strings
NOTE
Open the required AC and DC conduit drill guides according to the
conduits used in the installation. Taking care not to interfere with any
of the internal components. It is recommended to use a Unibit drill.
Use 19.1 mm or 25.4 mm Unibit drill to create holes for AC and DC
conduits.
Chapter 3: Installing the Inverter