© Solarbayer GmbH [02.16]
43
PRODUCT INFORMATION
Wood log boiler HVS
Boiler casing
Upper casing
When removing the front top plate you have to
unscrew the 2 self‐cutting screws at the front.
Afterwards remove the caps which are located in the
corners of the front plate with a slotted screwdriver.
Underneath the caps are self‐cutting screws which
only should be loosened. Pull the front plate approx. 2
cm to the front and then tilt it carefully to the front.
Left and right casing
First of all you have to remove the upper front plate as
described above. Afterwards the back top plate is
going to be removed as well. The upper and bottom boiler doors have to be closed tightly. When removing the top
plate at the side of the hinges the screw nuts that are rested against the galvanized support have to be loosened.
At the side of the closing you have to remove the two screws that are next to the door closing. Afterwards, remove
the casing of the forced draft fan. Unscrew all self‐cutting screws at the backside of the boiler casing to free both
side plates. Afterwards those can be removed.
Door casing
First off all, demount the complete door by removing the pintle from the hinges. Demount the door handle as
well. Place the door with the inner side facing downwards on a stable ground. Now the casing can easily be
removed.
Main
tenance
Disconnect boiler form the mains supply before removing the casing.
Never touch conducting devices – danger to life exists!