© Solarbayer GmbH [02.16]
59
PRODUCT INFORMATION
Wood log boiler HVS
Main
tenance
Maintenance report
Maintenance rate
Maintenance
with ev
ery filling
(daily)
with ev
ery fifth filling
(twice a w
eek)
with ev
ery 30
th
filling
(ev
ery 3 w
eek
s)
annual
Expansion vesselheating water
check [primary pressure: gas overpressure behind the vessel’s membrane if
the expansion vessel is depressurized on the water‐side; system pressure:
water overpressure of the cold system]
–
–
–
Safety installations
check operability [the thermal discharge safety valve opens automatically in
case of overheating and cools the boiler over the safety heat exchanger with
tap water; the manometer shows the recent overpressure of the system; the
pressure relief valve opens when necessay and thus limits the overpressure
to a max. of 3 bar]
–
–
–
Sealings, sensors, fireclay and flame‐swept parts are wear parts.
We recommend the annual maintenance to be carried out by a professional HVAC installer in accordance
with the valid safety and technical regulations.
Let your installer cofirm the annual maintenance operations.