39
August 2020
|
Solar Stik
®
, Inc.
24VDC PRO-Verter 7000-120 AGS Operator Manual
Range: 5 A to 60 A
Range: GEL, Flooded, AGM1 AGM2,
CC/CV
. . . . . . .
SETUP
Status
03 Charger Setup
03A AC Input
Amps = 40A
03C Battery Type
CC/CV
Set Battery Type
GEL
Set Battery Type
AGM1
Set Battery Type
AGM2
Set Battery Type
Custom
Default = 150
03B VAC Dropout
80VAC
Set Battery Type
CC/CV
Set CV Chg Done
HOLD CV/CHG VDC
Set CV Charge
Volts =
29.0
Set Max Charge
AMPS =
110
Set CV Chg Done
Time = 0.1-25.5Hrs
Set CV Chg Done
HOLD CV/CHG VDC
Options: Time, Hold,
CV, Chg, Amps
Set Max CC/CV
Time = 0.1-25.5 Hrs, off
Set Recharge
Volts = 24-32
Range: 0.0 to 25.5 Hrs
Range: Float, Silent, Multi
03F Max Charge
CC/CV Controlled
03G Final Charge
CC/CV Controlled
Set Max Charge
Time =12.0 Hrs
Set Final Charge
Stage = Silent
Set Final Charge
Stage = Float
Set Final Charge
Stage = Multi
Range: Time, Amps, SOC
Range: 0.1 to 25.5 Hrs
Range: 0 to 250 ADC
Range: 50% to 100%
03D Absorb Done
CC/CV Controlled
Set Absorb Done
Time = 1.0 Hrs
Set Absorb Done
Amps = 20 ADC
Set Absorb Done
SOC = 100%
Set Absorb Done
Time
Set Absorb Done
Amps
Set Absorb Done
SOC
03E Max Charge
Rate = 90%
Set Max Charge
Rate = 0-100%
Set Rebulk Voltage
Volts = 24.0
Range: 24.0 to 32.0 VDC
03H EQ Reminder
CC/CV Controlled
Set EQ Reminder
Days = 1-255 days
Setup: 03 Charger
SETUP Button Menus continued
Continued on next page
Info:
With CC/CV selected, the following
menus are no longer accessible and will
display “CC/CV Controlled” when they
are selected: 01D Max Charge Amps, 03D
Absorb Done, 03F Max Charge Time, 03G
Final Charge Stage, 03H EQ Reminder
Days. This is to prevent charging conflicts
that could occur while in the CC/CV profile.