12
®
®
5. Troubleshooting
Q. GODDESS
Royal Collection™ unit turned ON. Air blows out of T6000 Spray Gun?
• This is correct. Air blows constantly when GODDESS Royal Collection™ unit is ON.
Q. GODDESS Royal Collection™ unit turned ON. Unit does not operate or blow air?
• Check that the unit is plugged in to proper electric source. Be sure there is power at the electric source. If there is no
problem with electric supply, call for technical support.
Q. GODDESS Royal Collection™ unit is turned ON the trigger is pulled back on T6000 Spray Gun but no solution comes out?
• Check that the cup is screwed firmly to T6000 Spray Gun.
• Check that there is no solution bubbling or leaking around the cup.
• Turn GODDESS Royal Collection™ unit OFF. Unscrew cup. Be sure that Solution Tube and Disc (#14, Diagram
on page 6) is connected and has not come loose.
• Turn GODDESS Royal Collection™ unit OFF. Remove air cap ring (#1, Diagram on page 6) remove air cap (#2, Diagram
on page 6) remove air plate (#5, Diagram on page 6) remove the needle (#8, Diagram on page 6). Remove Solution nozzle
(#3, Diagram on page 6) with an adjustable wrench or spanner. There is a Solution nozzle gasket (#4, Diagram on page 6)
on the Solution nozzle. Do not lose it. Rinse Solution Nozzle under running water and check for dried solution that may have
blocked the hole. Reinstall Solution Nozzle Gasket. Reinstall Solution Nozzle, solution needle, air plate, air cap and air cap
ring. Try spraying again. If you still have a problem call for technical support.
Q. Solution leaks in front of trigger?
• With an adjustable wrench or spanner tighten Solution Needle Packing Screw (#7, Diagram on page 6). Do not
over tighten. This can cause Solution needle to stick and not spring back. Try spraying again. If leaking continues the
Solution Needle Packing needs to be replaced. (Rare). Remove solution needle (#8, Diagram on page 6), then remove
Solution Needle Packing Screw (#7, Diagram on page 6). Dry out the Solution Needle Packing’s (4) (#6, Diagram on page
6). Replace. Reinstall Solution Needle Packing Screw and solution needle. Tighten all the way, and then back off slightly.
(1/8 turn) Test the T6000 spray gun for leakage. If you still have a problem call for technical support.
Q. When GODDESS Royal Collection™ unit is ON, Solution continues to spray from the T6000 Spray Gun without trigger being
pulled?
• Immediately turn GODDESS Royal Collection™ unit OFF.
• Disconnect T6000 spray gun from air hose.
• Slightly adjust (loosen) Solution Needle Packing Screw (#7, Diagram on page 6). Test to see if problem is resolved.
• Check to see that Needle Spring is installed. (#9, Diagram on page 6). Remove Solution Flow Screw (#10, Diagram on page
6). Look for Needle Spring around the back of the Solution Needle. If lost, call for replacement.
• Check Solution nozzle. Remove and clean following the spray gun weekly clean directions on page 11.
Q. Solution leaks around the top of the cup.
• Make sure there is a gasket (#15, diagram on page 6)
• Make sure the cup is screwed firmly to the body of the T6000 Spray Gun.
• Make sure the threads around the cup are clean and the threads inside the cup top assembly are clean.
• Replace the cup top gasket. Pry out old gasket. Install new gasket. Test T6000 spray gun.