POWERPAK Owner’s Manual 

 

 

 

Issue Date October 2005

 

 

 

INSTALLATION INSTRUCTIONS 

 
GENERAL 
 

Installation of this water heater must be performed by an Authorised Person and in accordance with 

Local Authority Safety regulations, and Electrical and Plumbing Codes applicable in your area. In 

Australia, for example, the installation must comply to Australian Standard (AS 3500.4) “National 

Plumbing and Drainage Code, Part 4: Hot Water Supply Systems”. 

LOCATION SELECTION 

 

Collector Panels 

For optimum performance the collector panels should be installed to face the equator (South in the 

Northern Hemisphere, North in the Southern Hemisphere) 

ALWAYS USE A COMPASS TO CHECK 

ORIENTATION

. Deviation from the equator up to 45°East or West has little effect on total annual solar 

contribution (approximately 4 per cent). Should it not be possible to face the equator the decision of 

either EASTERLY or WESTERLY direction must be made.  

(a)  If major hot water draw is before 2 p.m. favour EASTERLY  

(b)  If major hot water draws after 2 p.m. favour WESTERLY. 

The westerly direction is more commonly used.  
The collector panels should be installed on a roof of pitch or angle that is the same as the latitude angle 

of the site. Roof angles within 20° of the latitude angle will have little effect on the total annual solar 

contribution (4%). Minimum roof angle is 10º for with-pitch installations. 
If it is necessary to face the collector panels 45°East or West of the equator then a flatter (lower pitch) 

installation will give better performance. Additional panels facing east or west may be more aesthetically, 

economically and thermally beneficial than mounting the Collector Panels on roof brackets to face the 

equator. 
The collector panels must be installed in an area that is free of shade all year round. Check high trees 

and other obstacles for winter shade. 
The collector panel location should not be more than 7 metres vertically, for a 10kW POWER

PAK 

above 

the base of the POWER

PAK

 with a maximum pipe run of 16 metres from the POWER

PAK

. For 

installations with greater distance than these please consult Solahart for revised pump sizes and 

configurations. 
 

POWER

PAK

 Module 

Select a suitable location near the hot water storage system to which the POWER

PAK

 is to be 

connected. As the POWER

PAK

 is weatherproof, the location may be internal or external. However, in 

cold climates an internal location is preferred.  
The POWER

PAK

 must be positioned such that the electrical socket is accessible. 

To minimise heat losses the POWER

PAK

 should be located as close as possible to the hot water 

storage system and at the same level. 

SAFETY

  

 

This appliance is not intended for use by young children or infirm persons without 

supervision.  

Young children should be supervised to ensure that they do not play with the 

appliance.

 

Important 

Additional information on installing the pipe work to and from the POWER

PAK

 can be 

found in Solahart Technical Bulletin #136. This can be obtained from your Solahart 

dealer or from Solahart directly.

 

Содержание POWERPAK 10 kW

Страница 1: ...ustries Pty Ltd ABN 45 064 945 848 Corporate Headquarters 112 Pilbara Street Welshpool Western Australia 6106 Postal address P O Box 95 Welshpool Western Australia 6986 Telephone International 61 8 93...

Страница 2: ...rnal Component Diagram 5 Electronic Controls 6 Installation Instructions 7 Location Selection 7 Collector Array Diagram 8 Collector Installation and Components 9 POWERPAK Module Installation 10 Commis...

Страница 3: ...POWERPAK Owner s Manual 2 Issue Date October 2005...

Страница 4: ...Hart a name which was retained for over 70 years Even in its early stages S W Hart was involved in the manufacture of metal products for water storage and water heating Since 1953 S W Hart now Solahar...

Страница 5: ...POWERPAK Owner s Manual 4 Issue Date October 2005...

Страница 6: ...or selectable functions and an overriding temperature comparator system The temperature comparator system monitors the temperature at the solar collectors and of the potable water storage system to de...

Страница 7: ...sioning purposes The Power light will be OFF and the circulation pump running light will be ON CLOSED CIRCUIT FLUID LEVEL FAULT INDICATOR This indicator will illuminate when the closed circuit fluid l...

Страница 8: ...ctor panels 45 East or West of the equator then a flatter lower pitch installation will give better performance Additional panels facing east or west may be more aesthetically economically and thermal...

Страница 9: ...OLLECTORS 1 Temperature Sensor 2 Collector flow connection 3 Collector return connection 4 Expansion Valve connection 5 Top collector rail 6 Bottom collector rail 7 Collector clamps NOTE The POWERPAK...

Страница 10: ...nuts correctly into the collector fittings Do not over tighten the connections as permanent cone damage may occur Locate the top rails with fixing straps attached snugly onto the collectors Remove ti...

Страница 11: ...at least 5 back to the POWERPAK on both flow and return lines If these lines are taken through the roof material suitable flashing procedures in line with local approval practice should be employed C...

Страница 12: ...cent the POWERPAK The POWERPAK must be positioned such that the power plug is accessible Where the POWERPAK is installed external to the building weatherproof fittings must be used If the power cord i...

Страница 13: ...ck assembly into the level port at the module 4 Attach the air pump to the connection valve and pump the system pressure up to 120 kPa on the gauge 5 Disconnect the air pump and check the valve for le...

Страница 14: ...small container of boiling water Within 1 minute the pumps should start Note If the pumps do not start then the sensors and sensor circuits must be checked in accordance with the procedure detailed i...

Страница 15: ...e If the cabling is correct the multimeter should indicate a resistance reading which reflects the temperature at the sensor location as shown on the table below F C Ohms Resistance F C Approx Ohms Re...

Страница 16: ...kilometre radius of the Solahart dealer from whom the unit was purchased Customers outside this area will be subject to freight and travelling charges incurred by the Solahart dealer conducting the wo...

Страница 17: ...POWERPAK Owner s Manual 16 Issue Date February 2004...

Страница 18: ...or details and conditions of warranty see the warranty section of this manual Please complete all details below Purchaser s Name Installation Address Suburb State Postcode Telephone H W Solahart Deale...

Страница 19: ...POWERPAK Owner s Manual 18 Issue Date February 2004 949100...

Отзывы: