Solahart POWERPAK 10 kW Скачать руководство пользователя страница 11

POWER

PAK

 Owner’s Manual 

 

 

10 

 

 

Issue Date February 2004 

 

Collector Return Line Connection 

Final connection is achieved by welding (where solder is permitted, the 

melting temperature must be greater than 220ºC) a “remote connection 

pipe” to the insulated copper pipe returning to the POWER

PAK

 system. 

The remote connection pipe is then inserted into the top collector fitting of 

the right hand collector. The connector is secured to the collector fitting 

using a standard gland nut supplied with the connector. Refer to the 

Collector Installation Diagram 
 

Collector Flow Line Connection 

Final connection is achieved by welding (where solder is permitted, the 

melting temperature must be greater than 220ºC) a “remote connection 

pipe” to the insulated copper pipe rising from the POWER

PAK

 system. The 

remote connection pipe is then inserted into the bottom collector fitting of 

the left hand collector. The connector is secured to the collector fitting using 

a standard gland nut supplied with the connector. Refer to the Collector 

Installation Diagram 

 

Collector To POWER

PAK

 Connections

 

Pipework 

Insulated copper DN15 (or nearest local equivalent) flow and return lines must be installed from the collector 

array to the POWER

PAK

 location. 

During installation it is very important to install a constant fall of at least 

5º back to the POWER

PAK

 on both flow and return lines

. If these lines are taken through the roof material, 

suitable flashing procedures in line with local approval practice should be employed. 
 

Collector Temperature Sensor Lead 

Install a 2 core, 0.75 mm

2

 Figure 8 cable between the temperature sensor in the collector array and the 

POWER

PAK

 

POWER

PAK

 MODULE INSTALLATION

 

Collector (Primary) Circuit Connection 

The flow and return lines from the collector array  

are connected to brass conetite sockets located  

on the top left side of the 

POWER

PAK

 as shown. 

 

 

POWER

PAK

 To Storage Hot Water System Inter Connection 

Pipework 

Install two insulated DN15 copper flow and return lines from the POWER

PAK

 to the storage hot water system.  

To minimise heat losses the POWER

PAK

 should be located as close as possible to the hot water storage 

system. 
The location of the connections to the hot water storage system must be determined by the supplier of the 

storage system. Any water storage tank connected to the potable water connections on the POWER

PAK

 must 

be protected with the appropriate valves and safety devices with a maximum setting of 1000kPa and 99°C. 
 
 
 

 

 

 

 

 

 

Weld Copper Flow 

Pipe Here

 

Collector Flow Connection 

(Pipe to Collector) (Blue)

 

Gland Nut 

Collector Return Connection 

(Pipe from Collector) (Red)

 

Weld Collector 

Return Line Here

 

Gland Nut

 

Important: If the water quality is poor or the mineral content high, a filter and/or water 

conditioner must be installed on potable water line to the PowerPAK.

 

Содержание POWERPAK 10 kW

Страница 1: ...ustries Pty Ltd ABN 45 064 945 848 Corporate Headquarters 112 Pilbara Street Welshpool Western Australia 6106 Postal address P O Box 95 Welshpool Western Australia 6986 Telephone International 61 8 93...

Страница 2: ...rnal Component Diagram 5 Electronic Controls 6 Installation Instructions 7 Location Selection 7 Collector Array Diagram 8 Collector Installation and Components 9 POWERPAK Module Installation 10 Commis...

Страница 3: ...POWERPAK Owner s Manual 2 Issue Date October 2005...

Страница 4: ...Hart a name which was retained for over 70 years Even in its early stages S W Hart was involved in the manufacture of metal products for water storage and water heating Since 1953 S W Hart now Solahar...

Страница 5: ...POWERPAK Owner s Manual 4 Issue Date October 2005...

Страница 6: ...or selectable functions and an overriding temperature comparator system The temperature comparator system monitors the temperature at the solar collectors and of the potable water storage system to de...

Страница 7: ...sioning purposes The Power light will be OFF and the circulation pump running light will be ON CLOSED CIRCUIT FLUID LEVEL FAULT INDICATOR This indicator will illuminate when the closed circuit fluid l...

Страница 8: ...ctor panels 45 East or West of the equator then a flatter lower pitch installation will give better performance Additional panels facing east or west may be more aesthetically economically and thermal...

Страница 9: ...OLLECTORS 1 Temperature Sensor 2 Collector flow connection 3 Collector return connection 4 Expansion Valve connection 5 Top collector rail 6 Bottom collector rail 7 Collector clamps NOTE The POWERPAK...

Страница 10: ...nuts correctly into the collector fittings Do not over tighten the connections as permanent cone damage may occur Locate the top rails with fixing straps attached snugly onto the collectors Remove ti...

Страница 11: ...at least 5 back to the POWERPAK on both flow and return lines If these lines are taken through the roof material suitable flashing procedures in line with local approval practice should be employed C...

Страница 12: ...cent the POWERPAK The POWERPAK must be positioned such that the power plug is accessible Where the POWERPAK is installed external to the building weatherproof fittings must be used If the power cord i...

Страница 13: ...ck assembly into the level port at the module 4 Attach the air pump to the connection valve and pump the system pressure up to 120 kPa on the gauge 5 Disconnect the air pump and check the valve for le...

Страница 14: ...small container of boiling water Within 1 minute the pumps should start Note If the pumps do not start then the sensors and sensor circuits must be checked in accordance with the procedure detailed i...

Страница 15: ...e If the cabling is correct the multimeter should indicate a resistance reading which reflects the temperature at the sensor location as shown on the table below F C Ohms Resistance F C Approx Ohms Re...

Страница 16: ...kilometre radius of the Solahart dealer from whom the unit was purchased Customers outside this area will be subject to freight and travelling charges incurred by the Solahart dealer conducting the wo...

Страница 17: ...POWERPAK Owner s Manual 16 Issue Date February 2004...

Страница 18: ...or details and conditions of warranty see the warranty section of this manual Please complete all details below Purchaser s Name Installation Address Suburb State Postcode Telephone H W Solahart Deale...

Страница 19: ...POWERPAK Owner s Manual 18 Issue Date February 2004 949100...

Отзывы: