Solahart POWERPAK 10 kW Скачать руководство пользователя страница 18

POWER

PAK

 Owner’s Manual 

 

 

17 

 

 

Issue Date February 2004 

 

 

POWER

PAK

 

INSTALLATION & WARRANTY REPORT 

 

Dear Customer, 

To register your warranty please ensure the following information is correct then sign and return to our 

Solahart Industries Pty Ltd freepost address: 

 

Solahart Industries Pty Ltd. 

Reply Paid Perth 354, 

Welshpool. 

Western Australia 6106 

 

WARRANTY:

  For details and conditions of warranty see the warranty section of this manual 

 

Please complete all details below 

 

Purchaser’s Name 

 

Installation Address 

 

Suburb 

 

State 

 

Postcode

 

 

Telephone 

H)   

W)   

Solahart Dealership 

 

Consultant 

 

 

Important Details

 

 

Installation Date 

 

Model - type 

 

Type of Installation 

(Please circle) 

New 

 

 

Existing 

 

 

Work Delivery Details 

 

 

 

POWER

PAK

 Serial No   

Collector Serial No’s 

1) 

2) 

3) 

 

4) 

5) 

6) 

 

7) 

8) 

 

Service’s Due 

 

Installers Name 

 

Comments 

 

 

 

 

 

 

 

 

Date: 

........................................

 

 

............................................. 

 

............................................. 

Signature:

 

Installer 

Customer 

 

 

White Copy:  Head Office         Yellow Copy:  Dealer             Blue Copy:  Sales Office                 Green Copy:  Manual

 

 

 

Содержание POWERPAK 10 kW

Страница 1: ...ustries Pty Ltd ABN 45 064 945 848 Corporate Headquarters 112 Pilbara Street Welshpool Western Australia 6106 Postal address P O Box 95 Welshpool Western Australia 6986 Telephone International 61 8 93...

Страница 2: ...rnal Component Diagram 5 Electronic Controls 6 Installation Instructions 7 Location Selection 7 Collector Array Diagram 8 Collector Installation and Components 9 POWERPAK Module Installation 10 Commis...

Страница 3: ...POWERPAK Owner s Manual 2 Issue Date October 2005...

Страница 4: ...Hart a name which was retained for over 70 years Even in its early stages S W Hart was involved in the manufacture of metal products for water storage and water heating Since 1953 S W Hart now Solahar...

Страница 5: ...POWERPAK Owner s Manual 4 Issue Date October 2005...

Страница 6: ...or selectable functions and an overriding temperature comparator system The temperature comparator system monitors the temperature at the solar collectors and of the potable water storage system to de...

Страница 7: ...sioning purposes The Power light will be OFF and the circulation pump running light will be ON CLOSED CIRCUIT FLUID LEVEL FAULT INDICATOR This indicator will illuminate when the closed circuit fluid l...

Страница 8: ...ctor panels 45 East or West of the equator then a flatter lower pitch installation will give better performance Additional panels facing east or west may be more aesthetically economically and thermal...

Страница 9: ...OLLECTORS 1 Temperature Sensor 2 Collector flow connection 3 Collector return connection 4 Expansion Valve connection 5 Top collector rail 6 Bottom collector rail 7 Collector clamps NOTE The POWERPAK...

Страница 10: ...nuts correctly into the collector fittings Do not over tighten the connections as permanent cone damage may occur Locate the top rails with fixing straps attached snugly onto the collectors Remove ti...

Страница 11: ...at least 5 back to the POWERPAK on both flow and return lines If these lines are taken through the roof material suitable flashing procedures in line with local approval practice should be employed C...

Страница 12: ...cent the POWERPAK The POWERPAK must be positioned such that the power plug is accessible Where the POWERPAK is installed external to the building weatherproof fittings must be used If the power cord i...

Страница 13: ...ck assembly into the level port at the module 4 Attach the air pump to the connection valve and pump the system pressure up to 120 kPa on the gauge 5 Disconnect the air pump and check the valve for le...

Страница 14: ...small container of boiling water Within 1 minute the pumps should start Note If the pumps do not start then the sensors and sensor circuits must be checked in accordance with the procedure detailed i...

Страница 15: ...e If the cabling is correct the multimeter should indicate a resistance reading which reflects the temperature at the sensor location as shown on the table below F C Ohms Resistance F C Approx Ohms Re...

Страница 16: ...kilometre radius of the Solahart dealer from whom the unit was purchased Customers outside this area will be subject to freight and travelling charges incurred by the Solahart dealer conducting the wo...

Страница 17: ...POWERPAK Owner s Manual 16 Issue Date February 2004...

Страница 18: ...or details and conditions of warranty see the warranty section of this manual Please complete all details below Purchaser s Name Installation Address Suburb State Postcode Telephone H W Solahart Deale...

Страница 19: ...POWERPAK Owner s Manual 18 Issue Date February 2004 949100...

Отзывы: