checked for possible damage. This would normally be found around sharp edges such as roof flashing etc.
If the multimeter shows a short circuit, than the cable to the sensor should be checked for possible damage. This
would normally be found around sharp edges such as roof flashing etc or a nail or staple through the cable.
If the cabling is correct the multimeter should indicate a resistance reading which reflects the temperature at the
sensor location as shown on the table below:
ºF
ºC
Ohms Resistance
ºF
ºC
(Approx) Ohms Resistance
41
5
25380
122
50
3600
50
10
19890
140
60
2490
59
15
15710
149
65
2090
68
20
12490
158
70
1750
77
25
10000
176
80
1250
86
30
8057
194
90
920
104
40
5326
212
100
680
TECHNICAL DATA
Dimension Detail
10 kW Module
Collector Panel Data
•
Selective Surface
•
Absorptivity = 0.93 (± 0.05)
•
Emittance = 0.12 (± 0.02)
•
Glass = Low Iron with 94%
transmittance
Solahart Collector Panel Details