26
9.3 TOTAL AREA / SEED DRILL WIDTH – C2
Two independent total areas can be marked.
Displaying the total area
1-
Select channel 2.
2-
Press
to display total areas 1 and 2 on the screen.
First, “tot. 1” will be displayed and immediately after-
wards the value in Ha will be shown.
Setting to zero the total areas
1-
Select channel 2.
2-
Press
to display.
3-
Press
and hold
for
more than 5 seconds.
Programming the working width
1-
Select channel 2 of the area.
2-
Press and hold
for more than 5 seconds until
the width value is displayed and, without releasing it,
press the central button to modify the flickering digit.
3-
Press
and hold the flickering digit for more than
5 seconds to modify its value.
4-
Release
all buttons to return to the normal state.
Working in micro mode
When working with the distributor in the micro-dosing
mode (for small hoppers and minimal doses), press and hold
button for more than 3 seconds until the arrow indicat-
ing the micro mode is displayed. In this situation, the moni-
tor will keep the speed and actual real working area.
Press and hold
for more than 5 seconds until the indi-
cating arrow disappears to resume normal position.
9.4 CONTROL PANEL WITH MARKER
PATHS (OPTIONAL)
The monitor provided comes programmed especially for
your model of seed drill. The user will only need to observe
the displayed values and no extra programming is required.
The monitor shows 6 different channels or readings, as well
as 3 different arrows showing the states.
C1
shows forward speed in m/sec.
C2
shows two different hectares (for example on partial and
one total hectare).
C3
tramlining.
C4
shows the fan’s rpm.
C5
shows the turning speed of the distributor’s axle’s in rpm.
C6
shows if the hopper’s seed level is too low.
9.4.1 TRAMLINING - C3
The displays defaults to the
channels after 10 seconds
(unless the Area Total was selected).
There are five systems of tramlining - symmetric, asymmet-
ric left, asymmetric right, 10 bout and 18 bout. The tramline
bout is programmable from 1 to 15 in symmetric, asymmet-
ric left and asymmetric right sequences.
Selection of asymmetric tramlining is denoted by a decimal
point on the display between the current bout number on
the left and the tramline bout number on the right. Left or
right asymmetric tramlininig is selected in the programming
mode.
Manually advance the bout number
Press
to advance the current bout number by 1.