24
GSR1700 CSX Operations Manual
Chapter 3
Receiver Interface
3.3.4
Occupation timer gauge
The occupation timer gauge indicates that sufficient
quality and quantity of data has been collected for
successful static data post-processing.
The occupation timer gauge has two modes:
•
Baseline Length
(default mode)
—The gauge indicates
occupation by baseline length. The LEDs will show solid
green. See Section 3.3.4.1,
, below, for more
details.
•
Elapsed Time
—The gauge indicates elapsed time since the
start of the survey. The LEDs will flash. See Section 3.3.4.2,
, page 25, for more details.
3.3.4.1
Baseline length mode
When the occupation timer gauge is configured to display
receiver occupation by baseline length, the LEDs will illuminate
to show the length of baseline that can be successfully post-
processed given the amount of raw data that has been collected.
See Table 12,
Occupation timer gauge, baseline length mode
NOTE
✉
For successful post-processing, it is assumed that there are no
adverse environmental conditions and that you have a data logging
interval of 10 seconds.
NOTE
✉
Contact your SOKKIA distributor if you want to change the mode.
5 –
4 –
3 –
2 –
1 –
GSR1700 CSX Operations Manual (OM-1700CSX Rev 2, 750-1-0077).book Page 24 Wednesday, December 3, 2008 2:32 PM