277
35. CHECKS AND ADJUSTMENTS
4. While the telescope is in Face 1,
sight the center of the target
correctly and press
[OK]
.
5. Wait untill a beep sound and
rotate the instrument 180° . Sight
the center of the target correctly in
Face 2 and press
[OK]
.
6. Press
[YES]
to set the constant.
• Press
[NO]
to discard the data
and return to the screen in step
4.
PROCEDURE Check 1: Perpendicularity of the reticle to the
horizontal axis
1. Carefully level the instrument.
2. Align a clearly visible target (the
edge of a roof for example) on
point A of the reticle line.
3. Use the telescope fine motion
screw to align the target to point B
on a vertical line.
If the target moves parallel to the
vertical line, adjustment is
unnecessary. If its movement
deviates from the vertical line,
have our service representative
adjust it.
35.4 Reticle
HA-R
ZA