236
31. OUTPUTTING JOB DATA
It is possible to output JOB data to a host computer.
• Connect the serial connector and the host computer with the interface cable.
• Complete the necessary communication settings in advance. Communication
setup can be performed in the JOB menu as well. Select “Comms Setup” in
<JOB>.
Interface cables: "36.2 Optional accessories"
Output format and command operations: "Communication manual"
• Measurement results, instrument station data, known point data, notes, and
coordinate data in the JOB is output.
• Known point data entered from an external instrument is not output.
• When “inch” is selected as the distance unit, data is output in “feet” or "US feet"
depending on the feet unit selected.
PROCEDURE
1. Connect CX and host computer.
2. Select “JOB” in Data Mode.
3. Select “Comms output” to display
the JOB list.
31.1 Outputting JOB Data to Host Computer
Data
JOB
Known data
Code
JOB
JOB selection
JOB details
JOB deletion
Comms output
Comms setup