[33]
Some of the key features of the unit are:
Corrosion free
No priming required
Quick fill and drain
Low and easy maintenance
INSTALLATION
The Equipment is Inbuilt with Power source. The equipment is designed for use in industrial
environments
The equipment is powered from a suitable power socket. Connect the outlet of the cooler unit to the
inlet of the welding unit. Connect the inlet of the cooler unit to the outlet of the welding unit.
IMPORTANT
—
The unit should be switched on at all times during welding to prevent damage to
torches and cables
Ensure the unit is filled with water and checked once the cables and hoses have been filled before the
start of the machine.
MAINTENANCE
WARNING: - BEFORE CARRYING OUT ANY INTERNAL INSPECTION DISCONNECT THE UNIT
FROM THE MAINS SUPPLY AND FROM POWER SOURCE
Periodically check the level of the cooling fluid
Add fluid when the level drops below the minimum level indicator
Add anti-freeze when the room temperature is below 20°C
Make sure all the joints are tight and there are no leaks
Periodically clean the radiator with clean dry air to eliminate blockages that may affect efficiency
IMPORTANT: - Always use original spare parts which have been specially designed for this equipment.
The use of alternate parts may affect the performance of the unit
After long periods of not being used ensure the water is circulating freely through the sys-tem
The pump may be damaged if run without sufficient coolant
Ensure the unit is connected to a suitable mains supply
The motor will not run if the mains voltage is too low, the start capacitor is defective, OR the motor is
defective OR the motor has not been used for a period of time. This may be corrected by pumping
compressed air into the water inlet or outlet connection for 20 seconds.
Содержание SI-TIG-300
Страница 31: ... 28 9 TIG WELDING TORCH DETAILS ...
Страница 32: ... 29 ...
Страница 33: ... 30 10 ARGON FLOWMETER REGULATOR DETAILS ...
Страница 34: ... 31 ...