[9]
Welding cables instruction
When welding, please pay attention to the followings:
a. The welding cables should be kept as short as possible;
b. If extended cable is used, please do as shown in Fig. 3-4-1.
Wrong
Coil the excess ground cable and welding cable in same
direction respectively.
Correct
Straighten the ground cable and welding cable and make
them close to each other.
Bundle the ground cable and welding cable together,
running the wires close to the ground.
Correct
When the excess cables are only be used by rolling up,
coil the cables to two windings in reverse direction and
overlap them.
The number of turns for A is same as the number for B.
Handle the welding cable and ground cable according to
above-mentioned method.
Welding cables instruction
Connecting to a mains electrical supply
THIS MACHINE IS OF AN INDUSTRIAL SPECIFICATION AND MUST BE FITTED TO A MINIMUM of
16AMP 415V MAINS INPUT
Connecting to an Engine Driven Generator
If connecting this machine to an engine driven generator please ensure the following
Minimum Generator KVA Output
–
20 KVA continuous
Generator to be fitted with AVR (automatic voltage regulation)
DO NOT USE ON A GENERATOR WITHOUT AVR
Connecting to a generator without the above minimum requirements will in-validate your
warranty.