SOFAR 7K~10.5KTLM-G3
User manual
Copyright © Shenzhen SOFAR SOLAR Co., Ltd
- 44 -
5. On-Off Control
Inverter on-off local control.
6. Set Energy
Set the total power generation. You can modify the total power generation
through this option.
7. Set address
Set the address (when you need to monitor multiple inverters simultaneously) ,
Default 01.
8. Set Input mode
SOFAR 7K~10.5KTLM-G3 has two MPPT channels, which can run
independently or in parallel. Users choose the operation mode of MPPT
according to the system design. Parallel mode is applicable to the case where
two channels are in parallel, independent mode is applicable to the case where
two channels of MPPT run independently, and the default mode is independent
mode.
9. Set Language
Set the inverter display language.
10. SetAntiReflux
Enable or disable the anti-reflux function of the inverter, and set the reflux
power. This function need to be used with external CT, please refer to this
manual 4.4.3 CT for details.
11. LogicInterfac
Enable or disable logical interfaces. Please refer to this manual 4.4.1 Logic
interface for details.
12. IV Curve Scan
Shadow scanning, when the component is blocked or abnormal, causing multiple
power peaks, by enabling this function, the peak point of maximum power can
be tracked.
13. PCC select
Choose the method to detect PCC on-grid point power/current.