![Sofar solar 3.3K- 5.5KTL-X Скачать руководство пользователя страница 38](http://html.mh-extra.com/html/sofar-solar/3-3k-5-5ktl-x/3-3k-5-5ktl-x_user-manual_1311971038.webp)
SOFAR 3.3K~12KTL-X
User manual
All rights reserved
©
Shenzhen SOFARSOLAR Co ., Ltd.
- 33 -
2. Provided the DC Power through the PV Pannel until the LCD is
working;
3. Set inverter country code as 02(Australia) in Enter Setting>Set Country
Code(password 0001)
;
4. Enable DRMs function in Enter Setting>Logic Interface(password
0001);
5. Only DRM0, DRM5, DRM6, DRM7, DRM8 has been defined. Inverter
will works as DRM0, DRM5, DRM6, DRM7, DRM8 when Corresponding
switch closure. Their priority is DRM0>DRM5>DRM6>DRM7>DRM8.
4.7. Safety check
Photovoltaic array
Before the inverter operation, need to be examined for the photovoltaic
array, Check Open circuit voltage of the each PV array whether accord with
the requirements.
-Ensure Open circuit voltage of the each PV array accord with the requirements;
-Ensure that the positive and negative polarity is correct.
SOFAR 3.3K~12KTL-X DC connect