Housing preparation
The box where the card is installed is considered to be a metallic and/or plastic
box.
Inside, the plate of the box is suggested to have a drilling pattern like the one
shown in figure 4, for the mounting of the card when using “mounting bars” (see
also ANNEX A). Consult drawings (see ANNEX A) for the drilling pattern of the card
it self.
Figure 5: Drilling pattern
Current measurement channel protection
The cables should be properly selected and sized according to the application
specifications. Voltage must not exceed 1000VDC. A fuse must be installed for
each current measurement channel separately, with rated current up to 16A.
CAUTION
Voltage must not exceed 1000VDC. A fuse must be installed for each current
measurement channel separately, with rated current up to 16A.
For the preparation of the cables connected to the current channels the IPC-620
have to be followed by the installer.
The cables should be connected to the current channels using ring terminals and
star washers above the ring terminal.
Connectors plug preparation
The connector plugs to be used are those listed in table 2 or equivalent.
For the preparation of the cables connected to the plugs the IPC-620 have to be
followed by the installer.
Plugs should be connected with cables before plugged to the card.
Содержание SNV018EC.XX
Страница 37: ...S N V 0 1 8 E C X X U S E R I N S T A L L A T I O N M A N U A L V 3 1 SNV Engineering Ltd 34 ...
Страница 38: ...S N V 0 1 8 E C X X U S E R I N S T A L L A T I O N M A N U A L V 3 1 SNV Engineering Ltd 35 ...
Страница 39: ...S N V 0 1 8 E C X X U S E R I N S T A L L A T I O N M A N U A L V 3 1 SNV Engineering Ltd 36 ...
Страница 40: ...S N V 0 1 8 E C X X U S E R I N S T A L L A T I O N M A N U A L V 3 1 SNV Engineering Ltd 37 ...
Страница 41: ...S N V 0 1 8 E C X X U S E R I N S T A L L A T I O N M A N U A L V 3 1 SNV Engineering Ltd 38 ...