When to Charge the iONMAX 40V 

Lithium-Ion Battery

NOTE: The iONMAX 40V lithium-ion battery packs do not 

develop a "memory" when charged after only a partial 

discharge. Therefore, it is not necessary to run down the

 

battery pack before placing it into the charger. 

•  Use the battery charge indicator lights to determine when 

 

to charge your iONMAX 40V lithium-ion battery packs. 

•  You can "top-off" your battery pack's charge before starting 

a big job or after a long day of use.

Charging the Battery Packs

1.  Check that the mains voltage is the same as that marked 

on the rating plate of the dual port battery charger. Then, 

insert the charger's plug into the electrical wall outlet. 

When you plug in the charger, the top green light will 

illuminate and stay green (Fig. 11).

2.  Place the battery packs into the dual port charger by 

sliding the packs as shown to lock it into position. When 

you insert the batteries into the charger, the bottom red 

light will illuminate to indicate that the battery is charging 

(Fig. 12).

3. 

When the bottom light turns green, the battery is fully 

charged (Fig. 12).

NOTE: If the top light remains green while the bottom light 

alternately flashes red and green, this indicates a temperature 

abnormality (i.e. that the battery pack is either too hot or too 

cold). If there is only a red blinking light, this indicates that 

something is wrong with the battery. Contact Snow Joe

®

 + 

Sun Joe

®

 customer service center at 1-866-SNOW-JOE  

(1-866-766-9563) for assistance.

4.  A fully discharged iONMAX 40V lithium-ion battery pack 

with an internal temperature in the normal range will fully 

charge in 4 hours (between 32ºF/0ºC and 113ºF/45ºC). 

A fully discharged iBAT40XRP battery pack with an 

internal temperature in the normal range will fully charge 

in 3 to 4.5 hours (between 32ºF/0ºC and 113ºF/45ºC). 

Heavily cycled battery packs may take longer to charge 

completely.

5.  If the charging light indicator alternately blinks red and 

green or the light indicator does not come on at all, check 

that the battery pack is fully seated into the bay. Remove 

the pack and reinsert. If the problem persists, contact the 

Snow Joe

®

 + Sun Joe

®

 customer service center at  

1-866-SNOWJOE (1-866-766-9563) for assistance.

6. 

When charging is complete, remove the battery from the 

charger by pulling the push lock button and sliding the 

battery backward to unlock it from the charger (Fig. 13).

7.  Timely recharging of the battery will help prolong the 

battery's life. You must recharge the battery pack when 

you notice a drop in the equipment's power.

IMPORTANT! Never allow the battery pack to become fully 

discharged as this will cause irreversible damage to the 

battery. 

Charging a Hot or Cold Battery Pack

A red and green flashing indicator light on the charger indicates 

that the battery pack temperature is outside the charging range. 

Once the pack is within the acceptable range, normal charging 

will take place and the red light will be continuous. Hot or cold 

battery packs may take longer to charge. 

Fig. 11

green

Power on

Fig. 12

green
red

Charging

green
green

Fully charged

Green

Flashing red/green

Temperature abnormal

Flashing red only

Something is wrong

Fig. 13

Push lock button

Содержание iON24SB-CT-RM

Страница 1: ...sure you get the most out of your product be sure to register online at to enjoy full product support PASTE UPC LABEL HERE A Division of Snow Joe LLC Model iON24SB CT RM Form No SJ iON24SB CT RM 880E...

Страница 2: ...ricating and changing accessories mWARNING Always disengage both triggers press down the safety switch turn off and remove the key from the switch and disconnect the battery packs wait for all movemen...

Страница 3: ...temperature Maintain charger cord When unplugging the charger pull the plug not the cord from the receptacle to reduce the risk of damage to the electrical plug and cord Never carry the charger by it...

Страница 4: ...tion for proper battery disposal 10 Use only original battery packs The use of other batteries poses a fire risk and may result in injuries or an explosion IMPORTANT Do not press the ON OFF switch any...

Страница 5: ...after replacing parts to ensure that the unit is functioning properly Preliminary area inspection Clear the area to be plowed before each use Remove all objects such as rocks broken glass nails wire...

Страница 6: ...motor remove the key and battery packs to prevent unauthorized use Check all controls frequently Check both triggers and safety switch frequently Adjust and service as required All motion of drive whe...

Страница 7: ...Keep dry CAUTION Beware of stones and other foreign objects that could be thrown from the appliance DANGER Cutting dismemberment hazard Keep hands away from the rotating auger Do not use hands to unc...

Страница 8: ...each Weight snow blower alone 98 1 lbs 44 5 kg Weight 103 5 lbs 47 kg snow blower with batteries installed Initial no load voltage when fully charged peaks at 80 volts nominal voltage under typical l...

Страница 9: ...for long term product storage IMPORTANT The equipment and packaging material are not toys Do not let children play with plastic bags foils or small parts These items can be swallowed and pose a suffoc...

Страница 10: ...n the gear plate and push down until the chute is flush and flat against the housing Fig 6 2 Using the 2 U bolts and 4 nuts secure the discharge chute assembly to the gear plate Fig 7 NOTE You may nee...

Страница 11: ...hoes 5 Retighten hex nuts securely Battery Pack Operation The equipment is powered by a lithium ion batteries The battery packs are completely sealed and maintenance free Battery Charge Level Indicato...

Страница 12: ...ischarged iONMAX 40V lithium ion battery pack with an internal temperature in the normal range will fully charge in 4 hours between 32 F 0 C and 113 F 45 C A fully discharged iBAT40XRP battery pack wi...

Страница 13: ...moving it up and down as depicted NOTE After you have finished using your snow blower remember to turn OFF the light switch Auger Trigger Right Handle Fig 16 1 Press the safety button then squeeze the...

Страница 14: ...using 5 Use the shovel shaped end of the clean out tool to dislodge and scoop any snow and ice which has formed in and near the discharge chute 6 Refasten the clean out tool to mounting clip on the to...

Страница 15: ...witch remove key and wait for all rotating parts to stop before leaving operator s position Operation mWARNING Failure to follow instructions could result in personal injury and or damage to snow blow...

Страница 16: ...leasing the drive trigger left handle mWARNING DO NOT change direction from forward to reverse with drive trigger left handle engaged Unit must come to a complete stop before changing direction Snow R...

Страница 17: ...use stop the snow blower remove the batteries and inspect for frozen parts Free all parts before restarting or operating the snow blower Never force controls that have frozen Traveling To travel from...

Страница 18: ...tand in front or over the tire assembly when inflating Use a clip on chuck and extension hose long enough to allow you to stand to one side Replacing Skid Shoes The skid shoes on the bottom of the sno...

Страница 19: ...freely on the shaft which may help prevent damage to the gearcase and its components mWARNING Always turn off the snow blower s motor and remove the key and batteries prior to replacing shear bolts 1...

Страница 20: ...olts from the side of the auger housing Fig 36 8 Remove 2 set of shear bolts and nuts from the auger Fig 37 9 Remove the auger bearings on both ends then remove the 2 auger blades from the auger shaft...

Страница 21: ...oving the 4 screws and washers 2 on each side and open the motor cover Figs 40 41 3 Remove the M6 bolt and sprocket cover from sprocket 1 then remove the auger belt from pulley 1 Fig 42 4 Roll the new...

Страница 22: ...s and around the spacers and the flange bearings bushings found at either end of the shafts Auger Gearcase Gearcases are filled to the correct level at the factory Unless there is evidence of leakage...

Страница 23: ...not in use Recharge the battery packs every 6 months to 50 capacity 2 lights on during off season storage to maintain optimal battery performance Battery Caution Disposal Information Always dispose of...

Страница 24: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occu...

Страница 25: ...iONMAX 40 V 5 0 Ah PRO SERIES Lithium Ion Battery Battery Charge Time Max iCHRG40 3 5 hours iCHRG40 DPC 4 hours Battery Run Time Max 40 min 2 batteries iONMAX 40 V 6 0 Ah PRO SERIES Lithium Ion Batte...

Страница 26: ...25 NOTES...

Страница 27: ...n this warranty shall be construed as obligating Snow Joe Sun Joe to incorporate such design changes into previously manufactured products nor shall such changes be construed as an admission that prev...

Страница 28: ...snowjoe com...

Отзывы: