5.4.2 Setup the Kahuna 360 Protocol
The Kahuna 360 TSL UMD (output only) protocol is setup in the
Engineering Configuration
– Protocols
menu.
1.
Use the
Loaded Protocols
parameter to select a free slot in the table, then use the
Protocol Type
parameter to select “Tally
& UMD”
. Use the
Available Protocols
parameter to select
TSL UMD (Output Only)
and then touch the {
Load
} button
(Fig 73.).
2.
To select an RS422 port on the Kahuna 360 mainframe, touch the {
Configure…
}
button on the
Engineering Config - Protocols
menu (Fig 73.).
3.
The
Engineering Config - Protocol Config
menu is displayed (Fig 74.). Touch the
Serial Port
attacher and then select which port you wish to use on the mainframe and
touch the {
Apply
} button.
Fig 73. Engineering Configuration - Protocols Menu
Fig 74. Select RS422 Serial Port