MV-32/64 Multiviewer
www.snellgroup.com
Operation
Issue 1 Rev 11
Page 28
© 2014 Snell Limited
4.1.1 Network settings
These settings only need to be manually entered if DHCP is not to be used. This would be
required for a network that uses fixed IP addresses and does not rely on a DHCP server to
allocate them automatically.
IP settings can be configured manually via the multiviewer web interface by using a PC or
MAC connected directly or via a LAN (see section 4.1.1.1). Direct connection is generally
easier, since the MV-32/MV-64 multiviewers default IP address may not match the current
LAN settings (refer to the section 4.2 for details on Using the web interface).
Both the single and dual MV-32/MV-64 multiviewers frame types are fitted with a pair of LAN
ports. Note that only the upper LAN port is operative on the single type MV-32/MV-64
multiviewer frame. In the case of the dual MV-32/MV-64 multiviewers frame, the lower port
serves the system on the left side of the frame when viewed from the front.
4.1.1.1
Setting a New Fixed IP Address using the Web Interface
See section 4.2 for details on connecting using a browser.
Once the browser has loaded the configuration screen, select 'Module', then 'Setup Module'.
Enter the correct IP settings and save. The MV will then close the configuration window and
restart with a new IP address.
You will need to enter this new IP address into your web browser to re-load the configuration
software and continue with the configuration of the unit.
4.1.2 Keyboard Operation
Any HID compliant USB keyboard can be used for the entry and editing of UMDs. The
keyboard is connected to the USB port on the front panel of the Multiviewer.
The [
Tab
] key activates the cursor on the topmost UMD. Successive Tab key operations move
the cursor on to the next UMD in sequence. The [
Esc
] key deactivates the cursor.
All multiviewer factory default settings (including the IP address) are restored by pressing
[
Ctrl
]-[
Alt
]-[
Del
] on the keyboard. This brings up a menu indicating which key should be
pressed next to determine the extent of restoration.
If the screen is not visible when doing a factory reset then the sequence is:
•
[
Ctrl
]-[
Alt
]-[
Del
] then [
1
] to only restore factory settings, or
•
[
Ctrl
]-[
Alt
]-[
Del
] then [
2
] to restore factory settings and delete all logos, layouts and
other user settings.
If any other key is pressed or no key is pressed in 60 seconds then the screen returns to the
normal multiviewer layout.
Note:
The IP address must be unique on the network. Please see your system administrator if
these details are required.
Содержание MV-32
Страница 2: ...MV 32 64 Multiviewer www snellgroup com Issue 1 Rev 11 Page 2 2014 Snell Limited...
Страница 6: ...MV 32 64 Multiviewer www snellgroup com Contents Issue 1 Rev 11 Page 6 2014 Snell Limited...
Страница 102: ...MV 32 64 Multiviewer www snellgroup com Connection to Other Equipment Issue 1 Rev 11 Page 102 2014 Snell Limited...
Страница 118: ...MV 32 64 Multiviewer www snellgroup com Hydra Open Protocol Issue 1 Rev 11 Page 118 2014 Snell Limited...
Страница 126: ...MV 32 64 Multiviewer www snellgroup com Technical Appendix Issue 1 Rev 11 Page 126 2014 Snell Limited...