4.15 External Audio Source Properties
Use this screen to set up audio reference levels and audio alarms associated with external
audio sources.
Fig 44. External Audio Source Properties
Digital Audio
Reference
Set the analog to digital reference level when applying an analog
meter scale to a digital source, or a digital meter scale to an analog
source. It can be set within the range of -30 to -3 dBfs.
Analogue Audio
Reference
Set the 0dB reference level with respect to analog meter scales. It
can be set within the range of -12dBu to +12dBu.
Note
: The Digital and Analog reference level adjustments above have no effect when digital
audio is used with a digital scale.
Alarms
section
Here the thresholds for Audio Loss, Audio Over and Antiphase
alarms can be set, along with the alarm enabling of individual
channels. The channels listed here relate to the external audio
sources.
Example
:
Channels selected under
Audio Loss
will trigger an alarm when the
audio level on the associated channel falls below the threshold set
above.
Fig 45. External Audio Source Properties.
Содержание MV-32
Страница 2: ...MV 32 64 Multiviewer www snellgroup com Issue 1 Rev 11 Page 2 2014 Snell Limited...
Страница 6: ...MV 32 64 Multiviewer www snellgroup com Contents Issue 1 Rev 11 Page 6 2014 Snell Limited...
Страница 102: ...MV 32 64 Multiviewer www snellgroup com Connection to Other Equipment Issue 1 Rev 11 Page 102 2014 Snell Limited...
Страница 118: ...MV 32 64 Multiviewer www snellgroup com Hydra Open Protocol Issue 1 Rev 11 Page 118 2014 Snell Limited...
Страница 126: ...MV 32 64 Multiviewer www snellgroup com Technical Appendix Issue 1 Rev 11 Page 126 2014 Snell Limited...