5.9
Lock Controls
This item allows the front panel to be locked-out
such that it is inoperative. This function can only be
entered in the Supervisor access mode.
To set this function, enter at Supervisor level,
select the
Lock Controls
item to reveal the
dialogue box.
Select either YES or NO and save.
The function is now set.
Note that if this function is set to
Lock Controls: YES
and the unit is powered-up, the message
Front Panel Locked by Supervisor!
will appear.
Access Level
The setup of the active front panel may be
accessed at various levels. At the highest level
(Supervisor) access is allowed to all functions. This
level may only be accessed by entering a
password. At lower levels (User and Engineer)
access is only allowed to a limited number of
functions.
As supplied the unit will be in a temporary
Supervisor mode with no password protected
access levels.
From the main menu select
Set Password
To enter the Supervisor level and set up a
password proceed as follows:
1. Power-down the unit
2. Hold down the
YC
button and power-up the
unit. Continue to hold down the button for a
few seconds while powering-up.
3. From the main menu select
Access Level
4. Using the spinwheel, select
Supervisor
and
press
Save
5. From the main menu select
Set Password
6.
The default password will be 0000. To change
the password select the line for digits 1, 2, 3
and 4, and using the spinwheel to select the
desired characters. Press
Save.
The password has now been set.
Selection levels are:
USER
Provides access to basic user
controls.
ENGINEER
Provides access to more controls
than at user level but less than at
supervisor level.
SUPERVISOR Provides access to all available
control functions.
To set up this function, rotate the spinwheel to the
desired level and select Save.
Note that the number of control functions available
at
the
various
levels
are
set
by
the
software/hardware of the module and are not user-
adjustable.
Version
This shows the Software version number. Press
OK to return to the previous menu.