3.9
Matching the Front Panel to a Gateway Address
If the NRS70 is to be used on a RollCall network with other equipment, it may be necessary to change the unit
address to that of a vacant network slot in order to avoid confusion between units.
If an address is already in use by the network the RollCall receive and transmit LEDs will flash alternately at a
1-second rate. In this event, the following steps must be taken to set a new unit address:
1. Select an unused network address for the unit.
2. Set the address using the two switches on the gateway card, which is located behind the front panel.
Position 0 on the left-hand switch will disable the RollCall function on the unit.
Addresses 00 to 0F are pre-arranged.
All other positions on these switches may be used to set the unit address in hex.
3. Restart the front panel by holding down the
C Gain
and
Hue
buttons together.
4. Select
Yes
to the front panel question
“Restart panel! Are you sure?”
5. Hold down the
C Gain
button to enter the setup mode.
6. When the message
“Setup mode”
is displayed, release the
C Gain
button.
7. Momentarily press the
C Gain
button.
8. Select
Auto-Connect
.
9. Ensure that the top two lines read
Auto-Connec\\\\snellwilcox.local\\root\\Marketing\\Prodmgmt\\Data00
?
by selecting
▶
if necessary.
10. On the third line, change the middle two numbers
0000 (35) 02
to match the network address selected in step 2 above.
11. Restart the unit.