IQMUX32
Controlling the IQMUX32 from the RollCall Control Panel
Issue 2 Rev 4
Page 33
© 2015 SAM
5.10.7 Log Field Descriptions
Log Field
Description
UPTIME=
Displays the time since the last restart in the format
ddd:hh:mm:ss.
OS_VERSION=
Displays the operating system name and version. For
example, KOS V115.
HARDWARE_VERSION=
Displays the hardware version number.
BUILD_NUMBER=
Displays the build number.
SN=
Displays the module serial number, which consists of an S
followed by eight digits.
LICENSED_OPTIONS=
Displays any specially licensed options, if applicable.
FIRMWARE_VERSION=
Displays the FPGA version.
REAR_ID=
Displays a rear panel identifier number.
REAR_STATUS=
Display the status of the rear panel. Valid values are:
•
OK
•
FAIL:Lost
SLOT_WIDTH=
Displays the rear panel slot width. For example, 1 or 2.
SLOT_START=
Displays the rear panel slot start (boot-up) number.
INPUT_N_STATE=
Displays the current input state. Valid values are:
•
OK
•
WARN:Mismatch
•
FAIL:Lost
Note:
WARN:Mismatch indicates that the input and output
standards are not the same.
INPUT_N_STANDARD=
This displays the current input signal standard. For example,
1080/29i.
If the input standard is not recognized or supported the field
will display: WARN:Unknown
INPUT_N_TYPE=
This displays the type of input as specified by the module’s
configuration. Valid values are 3G / HD /SD SDI.
INPUT_N_IDENT=
Display the input ID.
INPUT_N_SDI_ERRS=
Displays SDI errors. Valid values are:
•
OK
•
WARN
INPUT_N_SDI_ANC_ERRS=
Displays ANC errors. Valid values are:
•
OK
•
WARN