IQMUX32
Controlling the IQMUX32 from the RollCall Control Panel
Issue 2 Rev 4
Page 15
© 2015 SAM
5.
Controlling the IQMUX32 from the RollCall Control Panel
5.1 The Information Window
The information window is displayed in the upper-right corner of each screen and displays
basic information about the video and audio status of the module.
Select either
Video Status
,
Audio Input Status
or
Audio AES Status
to display the
corresponding information.
5.1.1 Video Status
When
Video Status
is selected, the video input status is displayed:
5.1.2 Audio Input Status
When
Audio Input Status
is selected, the status of the embedded audio input is displayed
where:
Name
Status
Description
Standard
IN1:
OK
FAIL
LOST
MISM
Input signal received
Input signal failed
No signal received
Mismatch format detected
Detected video input standard is
displayed, e.g.
1080/29i
(Blank if
input lost).
IN2:
OUT1:
OK
BLK
FRZ
PAT
Output signal delivered
Black output delivered
Frozen output delivered
Pattern output delivered
Selected video output standard is
displayed, e.g.
1080/29i
. A
$
symbol
indicates that the caption is enabled.
(Blank if disabled)
OUT2:
Name
Status
Description
Audio Embed Input 1
P
?
D
E
V
Channel is a PCM audio input.
No audio input is detected.
Signal is data (non-PCM, Dolby, etc.).
Signal is Dolby E.
V bit present on audio channel.
--------
Audio Embed Input 2
--------