10
5. Now rotate the SpinDial to the right until it comes to a stop (within one
revolution).
6. When the SpinDial comes to a stop the lock is open.
7. Turn your safe handle.
CHANGING THE LOCK BATTERY
Separate the DialRing from the EntryPad:
1. Pull up on the SpinDial release to disengage the electronics.
2. Rotate the EntryPad 180 degrees to gain access to the EntryPad bolt
which is located at the 6 o’clock position on the EntryPad.
3. Loosen the screw to disconnect the EntryPad from the DialRing.
4. Remove the EntryPad from the DialRing by pulling the EntryPad away
from the DialRing.
Note:
The Entrypad and dial ring are held together by magnets to prevent
the Entrypad from falling off when unscrewing.
5. Install a high quality 9V alkaline battery in the back of the EntryPad.
Embossed in the bottom of battery compartment you will see the
battery orientation markings: “+” and “-“. Install the battery with the
correct orientation as indicated by the “+” and “-“.