![Snap-On Vantage Ultra Скачать руководство пользователя страница 73](http://html.mh-extra.com/html/snap-on/vantage-ultra/vantage-ultra_user-manual_1307349073.webp)
66
Scope Multimeter
Optional Settings
Display Settings
The Display setting allows you to change the displayed value in the Vertical Scale icon to your
preference.
NOTE:
i
This setting ONLY changes the value displayed in the Vertical Scale icon.
Display Full Scale
- displays the value of the entire (full) scale
Example (
):
If the vertical scale is set to 1V, the value displayed is 1V.
Figure 5-31
Display Per Division
- displays the graduation value of the major scale divisions
Example (
):
If the vertical scale is set to 1V, the value displayed is 0.1V.
Figure 5-32