V3400 Service
73
REPLACEMENT OF POD COMPONENTS
CAMERA REPLACEMENT
To remove pod components, first identify the part in question and remove that section of pod cover. To
remove a camera board, first disconnect the power and control cables. Only the measurement cameras will
have motor control cables, the calibration camera has only a power cable connected. Next remove the four
phillips screws near the center of the board. Replace with service board in the reverse order followed by per-
forming RCP.
REPLACING THE MOTOR CONTROLLER
Remove the outside pod cover. Disconnect control and power cables from the board. To remove the Motor
Controller Board, use a long shank phillips screwdriver to access the four screws securing the board to the
pod chassis. Re-install service board in the reverse order.
NOTE: if the left side camera
is replaced the security key
will be required to be used to
activate the camera and load
security to the camera before
use. Reference instructions
TEaK0277J97c.
Содержание UHR Ultra
Страница 1: ...Service Manual Ultra UHR Ultra and V3400 WHEEL ALIGNER May 2014 ...
Страница 13: ...11 AC DC POWER DISTRIBUTION ...
Страница 14: ...12 AC DC POWER DISTRIBUTION ...
Страница 16: ...14 Theory of Operation Figure 2 Top Field of View Figure1 Side Field of View ...
Страница 19: ...17 Theory of Operation Configuration using single pole wheel clamp ...
Страница 46: ...44 NOTES ...
Страница 67: ...65 Diagnostics ...
Страница 68: ...66 NOTES ...
Страница 83: ......