41
CALIBRATION
16. Extend the plunger under the rear foot. Click
on
<NEXT>
when done.
congratulations!
You have successfully com-
pleted calibration.
ACTIVATE AND CALIBRATE THE RIDE
HEIGHT MEASURING DEVICE
From the
calibration menu
, click on the
system
Configuration
icon and click on
Ride height
Target
switch to activate the Ride Height Target
feature.
CALIBRATE
1. From the
calibration menu
, click on
Ride
height Target calibration
icon to begin the
calibration process.
2.
Locate the Ride Height Calibration fixture and
place the fixture on one of the lift runways so
the straight edge is toward the camera.
3. Select the side of the rack you are to calibrate
from.
4. Place the tip of the target pointer into the hole
in the base of the calibration fixture.
NOTE: ThE pOiNTER Tip musT
REmaiN iN ThE hOlE duRiNg all
sTEps Of calibRaTiON.
5.
Tilt the target to the first position. The reflec
-
tive surface of the target should be facing the
camera. The target should be steady during
each step.
Содержание UHR Ultra
Страница 1: ...Service Manual Ultra UHR Ultra and V3400 WHEEL ALIGNER May 2014 ...
Страница 13: ...11 AC DC POWER DISTRIBUTION ...
Страница 14: ...12 AC DC POWER DISTRIBUTION ...
Страница 16: ...14 Theory of Operation Figure 2 Top Field of View Figure1 Side Field of View ...
Страница 19: ...17 Theory of Operation Configuration using single pole wheel clamp ...
Страница 46: ...44 NOTES ...
Страница 67: ...65 Diagnostics ...
Страница 68: ...66 NOTES ...
Страница 83: ......
Страница 84: ...05 07 2014 2014 Impreso en U S A 309 Exchange Avenue Conway AR 72032 TEEWA546P4 Rev C ...