84
7.1.1-2
7.1.1-3
7.1.1-4
7.1.1-1
7.1.1-5
Trouble shooting
E89
A key is jammed.
Find and release jammed key.
Or:
Press STOP or ESC to check the pedal switch.
If the error cannot be eliminated, the pedal function
is switched off by pressing the STOP key or the ESC
key. Call service team.
E92
The gauge for measuring the distance and diameter
is faulty.
Call service team.
As long as the geodata measuring gauge is defective,
set the distance and rim dimensions using the menu
key and turning the wheel (Chapter 2.3.3).
E93
The gauge for measuring wheel width is faulty.
Call service team.
As long as the width measurement gauge is faulty,
enter the rim width using the menu key and turning
the wheel (Chapter 2.3.1).
H0 - Figure
7.1.1-
1
Wheel silent running cannot be improved with
balancing optimisation.
H1 - Figure
7.1.1-
2
Further optimisation is not recommended but is
possible.
H2 - Figure
7.1.1-
3
Weight minimisation is recommended, further
optimisation does not bring improvements.
H20 - Figure
7.1.1-
4
Correction plane cannot be found with the gauge for
measuring distance and diameter.
Measure the correction plane and set the dynamic
imbalance indicator.
H21 - Figure
7.1.1-
5
The position reached does not correspond to the
correction plane, in which the stick-on weight must be
applied with the gauge.
Turn the wheel to the position for application of the
stick-on weight on the relative correction plane.