Page 16
7.0 EXPLANATION OF PROGRAM CODES
Various functions and features can be programmed to
enhance operation. These programs are referred to as
“P Codes”. Activate the “P Code” programs by pressing
and holding the
P Button
while turning the shaft until the
desired number is displayed on the right display win-
dow. User Codes are explained as follows:
P1
Toggle between normal and fine mode.
P4
Adapter compensation mode
P3
Toggle switch between gram and ounce display
P12
The balancer has 4 counters that keeps track of total
number of cycles for a certain parameter. The bal-
ancer will automatically cycle through the counters
after P12 is pressed. The order of the counters are:
1. Display
“Ctr ALL”
for one second.
Counter number of all spins.
2. Display
“Ctr CAL”
for one second.
Counter number of spins since last calibration.
3. Display
“Ctr SrV”
for one second.
Counter number of service spins.
4. Display
“Ctr USR”
for one second.
Counter number of user spins.
P14
Shaft Calibration verification
P18
ALU-S mode (press balancing mode button to exit
and back to DYN mode)
P20
Motorcycle mode
P43
Read or reset operator counters, reads or allows
reset of all four operators. (A, B, C, D)
P44
Read or reset productivity of user. Display counter
number of default user only.
8.0 MAINTENANCE
BEFORE ANY MAINTENANCE OR RE-
PAIRS ARE ATTEMPTED THE MACHINE
MUST BE DISCONNECTED FROM THE
ELECTRIC SUPPLY.
This balancer does not require any special maintenance,
but the following precautions are required:
A.
Periodically wash all plastic parts with a glass
cleaner. Wipe with a dry cloth.
B.
Clean all adapters regularly with a nonflammable liq-
uid detergent all. Lubricate with a thin layer of oil.
C.
Periodically perform a routine calibration as outlined
on pages 14 and 15 of this manual.
9.0 TROUBLE SHOOTING
TROUBLE
CAUSE
REMEDY
When turning the machine on,
No electric power
Check the input voltage
the displays do not light
Defect in the electric/electronic system
Call the service center
for assistance
The machine gives random readouts. Machine unstable on the floor
Check that machine is stable
Water in the tire
Remove water from tire.
Loose adaptor
Tighten the adaptor firmly
Defective electronic board
Call the service center
for assistance
The machine does not stop after
Defective electronic component
Stop using the machine immedi
balancing cycle
ately and call the service
center for assistance
The balancer is slow to display when
This machine performs a self-test routine
This is a normal characteristic
powering machine up.
on start-up. There will be a delay of several of the machine
seconds before the display is activated.
If the parameter arm ceases to
Malfunction of the Parameter arm from
Replace the Parameter arm or
properly measure rim distance
either a failure of the electrical system
manually enter the parameters
causing machine lockup.
or harness connection failure.
to continue operation.