Page 15
Model EEWB308B Operators Manual
6.0 RIM OFFSET GAUGE CALIBRATION, P80
To recalibrate the Rim Offset gauge proceed as follows:
1. Make sure the Rim Offset Gauge Arm is at home
position and no adapter or wheel is mounted as shown
in Figure 18.
Figure 18
2. Activate the gauge calibration program, “P 80” by
pressing and holding P button and rotate the shaft until
80 is displayed on right display window.
3. The right display will read "CAL SAP" for one sec-
ond. This means CALibration SAPe. Then it displays
"SAP OUT". The SAPE calibration procedure is acti-
vated.
4. Gently pull the SAPe arm OUT until it is fully ex-
tended, Figure 19, hold it steady for about 1 second.
Figure 19
5. The display will now read " H POS" with a short
beep sound. This is a reminder to return the arm back
to its Home POSition.
6. Once the Rim Offset Gauge Arm is returned to its
home position, machine displays "GOO D " with a con-
firmation beep. The calibration is finished.