Symptom
Possible Cause
Remedy
Machine does not turn on
• Power cord not plugged in
– Plug in cord
• No power in AC outlet
– Check power source
Refrigerant not being
• Hand valves not open
– Open hand valves
removed from vehicle
• Recovery tank full.
– Change tank or Charge
refrigerant
Excessive purging of
• Fitting(s) not properly
– Tighten fitting(s) finger tight
non-condensables
connected to master filter
• Leaky service hose or
– Tighten fittings or
adaptor connection drawing
replace seals in
in air
finger tight fittings
Does not charge
• Blue hand valve on recovery
– Open blue hand valve
tank not open
• Fitting not properly
– Tighten fitting finger tight
connected to recovery tank
• No refrigerant in tank
– Fill tank with refrigerant
Machine does not draw
• Loose hose connection
– Tighten loose hose
a vacuum
connections
• Oil drain valve open
– Close oil drain valve
Hissing noise from oil
• Oil drain valve open
– Close oil drain valve
separator during recycle
and/or vacuum mode
Refrigerant losses from
• Leaky hand valve(s) on tank
– Make sure hand
tank on scale over time
valves are either open
completely(CCW) or closed
completely (CW) and
leak test
• Leaky fitting(s)
– Oil seal with refrigerant oil
and reconnect OR,
replace fitting, oil seal
and reconnect
Long recycle times
• System being recycled is
– Heat A/C system by
cold and has components that
running engine with
hold a substantial amount of
A/C OFF and keep hood
liquid refrigerant
closed as much as practical
to hold in heat
Содержание Dual 3412
Страница 2: ...ii T Ta ab bl le e o of f C Co on nt te en nt ts s ...
Страница 8: ...viii U Us si in ng g t th hi is s M Ma an nu ua al l ...
Страница 14: ...VI S Sa af fe et ty y I In nf fo or rm ma at ti io on n ...
Страница 26: ...1 12 I In nt tr ro od du uc ct ti io on n ...
Страница 46: ...3 4 M Ma ai in nt te en na an nc ce e ...