Maaiinntteennaannccee
Master Filter
Change the master filter when the moisture indicator is violet or
when the hour meter has accumulated
20
additional hours since
the last master filter change. Any hours already showing on the
meter when unit is originally un-boxed and setup should be
noted on the next page as the first entry. These should not be
included in the first filter change interval, but considered the
starting point. Refer to the Moisture Indicator Chart below.
Complete the
Master Filter Maintenance Schedule
on the
following two pages to track when to change master filter.
Moisture Indicator
Figure 3-1: Moisture Indicator Chart
Moisture Indicator Chart
Indicator Color Model
Temperature
75°F/24°C
100°F/38°C
125°F/52°C
Purple
R-12
1.4 ppm
2.5 ppm
4 ppm
Very Dry
R-134a
20 ppm
35 ppm
60 ppm
Violet
R-12
5 ppm
9 ppm
15 ppm
Dry/Caution
R-134a
35 ppm
55 ppm
85 ppm
Pink
R-12
15 ppm
27 ppm
45 ppm
Caution/Wet
R-134a
90 ppm
120 ppm
150 ppm
Orange
R-12
25 ppm
43 ppm
70 ppm
Very Wet
R-134a
130 ppm
160 ppm
190 ppm